User’s and installation manual SWIMSPA – FITNESS POOL
English
41902E 26 EN-V00
x
Fit the aforementioned plastic spanner in
the front side of the spotlight and turn it
in order to release its bayonet fastening.
x
Change the lamp (press fastening).
x
Reassemble the spotlight making sure to
fasten the bayonet of the front part with
the spanner and pressing sufficiently to
prevent water from entering the spotlight.
x
Assemble the trim of the spotlight.
If you have any doubt about the explanation
of this operation, contact your authorised
dealer or authorised technical service
MAINTENANCE IN PERIODS OF NON-
USE OR ABSENCE
SHORT PERIODS (3-5 DAYS)
x
Adjust the pH and treat the water (see
Water Maintenance section).
x
Cover the spa.
x
Before using the Spa again, readjust the
pH and treat the water again.
PROLONGED PERIODS (5-14 DAYS)
x
Set the temperature at its lowest level.
x
Adjust the pH and treat the water (see
Water Maintenance section)
x
Cover the Spa.
x
Before using the Spa again, reset the
temperature as required , readjust the pH
and treat the water again.
PREPARATION FOR WINTER
If it is not planned to use the Spa through the
winter season or for prolonged periods of
time, the following operations should be
done:
x
Disconnect the electrical equipment,
placing the differential switch tab in the
OFF position.
x
Locate the drain valve (see
Drainage of
the Spa)
and turn the red lever of the
valve to the OPEN position. The Spa will
empty by gravity through the general
drain.
x
Leave the drain valve open.
x
Remove the filter cartridge/s from the
filter (See Maintenance of the filter) and
keep in a dry place.
x
Clean and dry the Spa.
x
Cover the Spa.
Do not leave water in the Spa without
electrical connection outdoors at
temperatures below 4ºC, as the pipes can
freeze and damage the Spa.