SG-B SERIES STEAM GENERATOR
8 E005-28-10-12
The following table should be referred to for guidance only. Please note that the size of heater required to
heat a particular size of steam room will vary according to a number of factors including the type of
material used for construction, the height of the steam room and the ambient temperature.
For lightweight materials such as plastics and laminates 1 KW will heat up to 1 cubic meter of air for dense
materials such as stones and ceramics which will conduct the heat away more rapidly allow for up to 2KW
per cubic meter of air. Hot air rises so restricting the height to around 2 meters will ensure the user is sitting
in the steam for higher ceilings you may need to increase the power requirement.
The following table is given as a guide, ambient air temperatures and frequency of use (number of door
openings) can also affect the power requirements.
Installation
The steam generator should be installed in dry well ventilated place in close proximity to the steam room. It
can be placed on the floor or hung on wall. In order for installing and maintenance, please refer the Fig-7 to
prepare enough space .
To hang the generator on a wall drill 3 holes 8mm in diameter in accordance with the table below and use
the wall plugs and screws provided. Fix the top 2 screws in place first then hang the generator by the 2
keyhole shaped holes in the back plate. Then with the front cover removed fix the 3rd screw to secure the
unit in place.
OC-B
(
)
c ontroller
can be either in or
out of s team room
OC-B s team generator
insulation
closet
steam noz z le
under was hing basin
bas ement
Fig-6
Min500
M
in
30
0
Min400
Min500
Unit
:
(
mm
)
Summary of Contents for OC-105B
Page 1: ......