Aqua OC-105B User Manual Download Page 3

SG-B SERIES                                                                                                                                    STEAM GENERATOR 

E005-28-10-12                                                                                                                                                                3 

 

SG- 90B 

OC- 90B 

9. 0 

230/ 400 

1/ 3 

39/ 13 

530

×

210

×

370 

SG- 105B 

OC- 105B 

10. 5 

230/ 400 

1/ 3 

45. 6/ 15 

530

×

210

×

370 

SG- 120B 

OC- 120B 

12. 0 

230/ 400 

1/ 3 

52. 0/ 17 

530

×

210

×

370 

SG- 135B 

OC- 135B 

13. 5 

230/ 400 

1/ 3 

56. 0/ 19. 5 

530

×

230

×

460 

SG- 150B 

OC- 150B 

15. 0 

230/ 400 

1/ 3 

65/ 21. 7 

530

×

230

×

460 

SG- 180B 

OC- 180B 

18. 0 

230/ 400 

1/ 3 

78. 0/ 26. 1 

530

×

230

×

460 

 
Remarks  if  greater  power  is  required  one 

OC-B 

controller  may  be  used  to  control  two  or  more  steam 

generators, e.g. if you need a 30KW steam generator you can use one OC-B controller to control two 15kw 
steam generator or three 10 kw steam generators . 
 

OC -B C on tro ller

To N e xt Sla ve

M a st er

Sla ve1

Sla ve 2

Tem p eratu re se nso r

 

 

 

(Fig-1) 

 

J3

From Ma st e r

J4

To Slave

To Next Slave

Master

Slave1

Slave2

Temperature

 sensor

OC-B Controller

 

(Fig-2) 

Summary of Contents for OC-105B

Page 1: ......

Page 2: ...solator This equipment must be installed by a competent person Disconnect the power supply before exposing electrical connections Confirm the right voltage to your steam generator 1 or 3 phase SAFETY...

Page 3: ...7 530 230 460 SG 180B O C 180B 18 0 230 400 1 3 78 0 26 1 530 230 460 Remarks if greater power is required one OC B controller may be used to control two or more steam generators e g if you need a 30K...

Page 4: ...the time widow displays Long the generator will operate continuously until it is switched off OC S 30 60 60 Steam on demand switch press once it will work 30 minutes press again it stop works special...

Page 5: ...12MPa 10 Overheat switch Boil dry protector operates at 110 11 Main circuit board Control center 12 Accessorial circuit board Connect and control the heat element 13 terminal Connection for power supp...

Page 6: ...r LED for over heat red means the steam generator was cut off as the heat element is too hot lack of water the heat elements may worked in air 16 Fan LED Indicator LED for Fan the lamp of steam room i...

Page 7: ...re that the track of the pipe does not create a trap into which condensate would gather and cause a blockage I e the pipe must not go down and then up There must be no valve or other blockage in the s...

Page 8: ...the power requirement The following table is given as a guide ambient air temperatures and frequency of use number of door openings can also affect the power requirements Installation The steam genera...

Page 9: ...e steam nozzle should be installed in the place which is far from the seat 300 overheat switch Fig 8 d Connect the drain outlet to a suitable drain via a copper pipe with the appropriate fittings e Ma...

Page 10: ...in place and then connect to the wire from the controller temperature sensor 4 scr ew Fig 10 Installation for power supply and control cable Confirm the correct voltage of power supply and wires Remov...

Page 11: ...in On RED D5 Liquid Inlet On RED D4 Reserve1ON RED D3 Light On RED D2 D1 RED Fan On LED COLOR KEY Fig 11 Tank H2 H1 V DC5V Switch C F 4 4 2 7 12Kw Steam Generator Circuit Diagram 2 JP1 OC S Controller...

Page 12: ...ve the knock out for the control cable entry and use a rubber grommet to protect the cable connect the cable to the relevant port on circuit board Ensure the power supply wire and control cable remain...

Page 13: ...display counts down to show the remaining time when it reaches 0 the steam generator will stop heating 8 Once the steam generator has operated for 10 minutes or more when it is turned off manually or...

Page 14: ...he OFF mode i e the boiler has finished steaming the water has drained and flushed the drain LED is off Before auto descaling can commence a supply of dilute citric acid liquid must be connected from...

Page 15: ...anel 5 control cable or port 4 if use circuit board the steam generator can work normally check the control cable port and controller Something wrong with 1 indicator LED for water level is red check...

Page 16: ...rcial operators we recommend the use of a water softener All users commercial and domestic must ensure a regular maintenance routine for descaling the generator The frequency of this will vary accordi...

Page 17: ...ators are guaranteed for 12 months from the date of purchase This guarantee excludes consumable items such as the electrical elements and failures resulting from misuse or abuse such as a failure to d...

Reviews: