Aqua OC-105B User Manual Download Page 2

SG-B SERIES                                                                                                                                    STEAM GENERATOR 

  2                                                                                                                                                          E005-28-10-12   

 

FOREWORD 

        Thank  you  for  choosing  our

  Aqua 

SG

-B  Series

 

steam  generator,  please  take  the  time  to  read  these 

instructions  before  you  begin  as  they  contain  important  information  about  the  installation  operation  and 
maintenance requirements. 
SG-B Series steam generators are available in specifications from 3kw to 18kw and are equipped with our

 

OC-B

 

intelligent controller. With this you can control not only the temperature and time duration of your 

steam bath but also the light and  fan  of the steam room  if installed, the automatic drain  valve,

 

automatic 

descaling, change the temperature display between Centigrade and Fahrenheit; alter the working mode,

 

as 

well  as  displaying  the  steam  generator's  status  by  the  8  LEDs  on  the  panel.  Please  note  also  that  one 

OC-B

 controller can control multiple SG-B Series steam generators. 

Every  SG-B  Series  steam  generator  is  thoroughly  tested  before  leaving  the  factory  so  there  may  be  the 
remains of water inside the boiler. 
 
IMPORTANT   

  read the manual before installation and operation 

  This appliance must be connected to an all pole isolator 

  This equipment must be installed by a competent person 

  Disconnect the power supply before exposing electrical connections. 

  Confirm the right voltage to your steam generator 1 or 3 phase. 

 
SAFETY PRECAUTIONS for steam bathing 

  Elderly  persons,  pregnant  women,  or  those  who  is  suffering  heart  disease,  high  blood  pressure, 

diabetes or not in good health are advised to seek medical opinion before using a steam room. 

  Do not smoke in the steam room 

  Avoid using the steam room immediately after strenuous exercise   

  Do not use the steam room when under the influence of alcohol 

  Leave the steam room at once if you feel sleepy, sick or uncomfortable. 

  Ensure good ventilation through the steam room 

 10cubic meters per bather per hour recommended. 

  We do not recommend this product is used by children under 16. 

  Commercial operators should post a notice of these precautions in a prominent position 

 

Chapter one:  Specification 

 
Please note that may not all models be available from your dealer.(chart 1) 

Code 

Model

 

Power   

(KW)

 

Voltage     

(V)

 

Phase       

(N~)

 

Current     

(A)

 

Dimensions(mm)                             

(L

×

W

×

H)

 

SG- 30B 

OC- 30B 

3. 0 

230/ 400 

1/ 3 

13/ 4. 3 

530

×

180

×

330 

SG- 40B 

OC- 40B 

4. 0 

230/ 400 

1/ 3 

17/ 5. 8 

530

×

180

×

330 

SG- 45B 

OC- 45B 

4. 5 

230/ 400 

1/ 3 

19. 5/ 6. 5 

530

×

180

×

330 

SG- 60B 

OC- 60B 

6. 0 

230/ 400 

1/ 3 

26. 4/ 8. 7 

530

×

180

×

330 

SG- 80B 

OC- 80B 

8. 0 

230/ 400 

1/ 3 

34. 8/ 13 

530

×

210

×

370 

Summary of Contents for OC-105B

Page 1: ......

Page 2: ...solator This equipment must be installed by a competent person Disconnect the power supply before exposing electrical connections Confirm the right voltage to your steam generator 1 or 3 phase SAFETY...

Page 3: ...7 530 230 460 SG 180B O C 180B 18 0 230 400 1 3 78 0 26 1 530 230 460 Remarks if greater power is required one OC B controller may be used to control two or more steam generators e g if you need a 30K...

Page 4: ...the time widow displays Long the generator will operate continuously until it is switched off OC S 30 60 60 Steam on demand switch press once it will work 30 minutes press again it stop works special...

Page 5: ...12MPa 10 Overheat switch Boil dry protector operates at 110 11 Main circuit board Control center 12 Accessorial circuit board Connect and control the heat element 13 terminal Connection for power supp...

Page 6: ...r LED for over heat red means the steam generator was cut off as the heat element is too hot lack of water the heat elements may worked in air 16 Fan LED Indicator LED for Fan the lamp of steam room i...

Page 7: ...re that the track of the pipe does not create a trap into which condensate would gather and cause a blockage I e the pipe must not go down and then up There must be no valve or other blockage in the s...

Page 8: ...the power requirement The following table is given as a guide ambient air temperatures and frequency of use number of door openings can also affect the power requirements Installation The steam genera...

Page 9: ...e steam nozzle should be installed in the place which is far from the seat 300 overheat switch Fig 8 d Connect the drain outlet to a suitable drain via a copper pipe with the appropriate fittings e Ma...

Page 10: ...in place and then connect to the wire from the controller temperature sensor 4 scr ew Fig 10 Installation for power supply and control cable Confirm the correct voltage of power supply and wires Remov...

Page 11: ...in On RED D5 Liquid Inlet On RED D4 Reserve1ON RED D3 Light On RED D2 D1 RED Fan On LED COLOR KEY Fig 11 Tank H2 H1 V DC5V Switch C F 4 4 2 7 12Kw Steam Generator Circuit Diagram 2 JP1 OC S Controller...

Page 12: ...ve the knock out for the control cable entry and use a rubber grommet to protect the cable connect the cable to the relevant port on circuit board Ensure the power supply wire and control cable remain...

Page 13: ...display counts down to show the remaining time when it reaches 0 the steam generator will stop heating 8 Once the steam generator has operated for 10 minutes or more when it is turned off manually or...

Page 14: ...he OFF mode i e the boiler has finished steaming the water has drained and flushed the drain LED is off Before auto descaling can commence a supply of dilute citric acid liquid must be connected from...

Page 15: ...anel 5 control cable or port 4 if use circuit board the steam generator can work normally check the control cable port and controller Something wrong with 1 indicator LED for water level is red check...

Page 16: ...rcial operators we recommend the use of a water softener All users commercial and domestic must ensure a regular maintenance routine for descaling the generator The frequency of this will vary accordi...

Page 17: ...ators are guaranteed for 12 months from the date of purchase This guarantee excludes consumable items such as the electrical elements and failures resulting from misuse or abuse such as a failure to d...

Reviews: