SG-B SERIES                                                                                                                                    STEAM GENERATOR 

  16                                                                                                                                                          E005-28-10-12   

 

Temp.    window 
display 

LC

 

Something is wrong with the 
Temperature Sensor 
connection 

Check connection or change Temperature 
Sensor 

1.   Check Temperature Sensor connection   

Temp.    window 
display 

HC

 

Temperature Sensor is short 
circuit 

2.   check controller if it is short circuit inside 

Turn off steam 
generator,water flow 
out from steam 
nozzle   

Something is wrong with 
water inlet valve 

Check water inlet valve .clean it or change it 

Something wrong with: 
1.water inlet valve   

cut off power 
supply , water flow 
out from steam 
nozzle   

2.circuit board 

Change circuit board or water inlet valve 

Something wrong with: 
1.       circuit board 
2.       controller 
3.       relays on accessorial 
circuit board 

Turn off steam 
generator .it still 
working 

4.       water level probe 

Cut power supply at once .contact dealer at 
once     

 

Chapter six: Maintenance 

The single biggest  problem  with steam  generation is the build up  of scale resulting from  dissolved solids 
within the water. Scaling can cause the elements to fail, the water level sensors not to function, premature 
failure  of  the  O  rings  resulting  in  leaks  from  around  the  elements.  The  extent  of  the  problem  will  vary 
according to the degree of hardness in the local water supply. 
For all commercial operators we recommend the use of a water softener. 
All users commercial and domestic must ensure a regular maintenance routine for descaling the generator.   
The  frequency  of  this  will  vary  according  to  the  degree  of  hardness  in  the  local  water  supply  and  the 
amount  of  time  the  generator  is  used.  Check  the  water  for  hardness  and  arrange  the  descaling  routine 
accordingly.   
High levels of hardness descale once every 50 to 100 hours of operation 
Medium levels of hardness descale once every 100 to 250 hours operation 
Low levels of hardness descale once every 250 to 1000 hours of operation. 
To  descale the  generator use a solution  of  weak acid crystals (such as citric acid)  mixed with water. The 
citric  acid  crystals  are  available  in  sachets  for  descaling  kettles  from  most  hardware  stores,  commercial 
operators  in  hard  water  areas  may  wish  to  purchase  large  quantities  from  specialist  outlets.  Follow  the 
instruction supplied with the crystals and allow sufficient time for the solution to dissolve the scale before 
flushing out the generator. 
Faults arising from a failure to descale the generator are not covered by warranty. 
Because  heating  and  cooling  cause  expansion  and  contraction  it  is  important  to  inspect  all  the  water  and 
steam inlets and outlets as well as their pipes and connectors on a regular basis to ensure there are no leaks. 
Clean the filter net in the magnetic valve according to the water quality in the location. 

Summary of Contents for OC-105B

Page 1: ......

Page 2: ...solator This equipment must be installed by a competent person Disconnect the power supply before exposing electrical connections Confirm the right voltage to your steam generator 1 or 3 phase SAFETY...

Page 3: ...7 530 230 460 SG 180B O C 180B 18 0 230 400 1 3 78 0 26 1 530 230 460 Remarks if greater power is required one OC B controller may be used to control two or more steam generators e g if you need a 30K...

Page 4: ...the time widow displays Long the generator will operate continuously until it is switched off OC S 30 60 60 Steam on demand switch press once it will work 30 minutes press again it stop works special...

Page 5: ...12MPa 10 Overheat switch Boil dry protector operates at 110 11 Main circuit board Control center 12 Accessorial circuit board Connect and control the heat element 13 terminal Connection for power supp...

Page 6: ...r LED for over heat red means the steam generator was cut off as the heat element is too hot lack of water the heat elements may worked in air 16 Fan LED Indicator LED for Fan the lamp of steam room i...

Page 7: ...re that the track of the pipe does not create a trap into which condensate would gather and cause a blockage I e the pipe must not go down and then up There must be no valve or other blockage in the s...

Page 8: ...the power requirement The following table is given as a guide ambient air temperatures and frequency of use number of door openings can also affect the power requirements Installation The steam genera...

Page 9: ...e steam nozzle should be installed in the place which is far from the seat 300 overheat switch Fig 8 d Connect the drain outlet to a suitable drain via a copper pipe with the appropriate fittings e Ma...

Page 10: ...in place and then connect to the wire from the controller temperature sensor 4 scr ew Fig 10 Installation for power supply and control cable Confirm the correct voltage of power supply and wires Remov...

Page 11: ...in On RED D5 Liquid Inlet On RED D4 Reserve1ON RED D3 Light On RED D2 D1 RED Fan On LED COLOR KEY Fig 11 Tank H2 H1 V DC5V Switch C F 4 4 2 7 12Kw Steam Generator Circuit Diagram 2 JP1 OC S Controller...

Page 12: ...ve the knock out for the control cable entry and use a rubber grommet to protect the cable connect the cable to the relevant port on circuit board Ensure the power supply wire and control cable remain...

Page 13: ...display counts down to show the remaining time when it reaches 0 the steam generator will stop heating 8 Once the steam generator has operated for 10 minutes or more when it is turned off manually or...

Page 14: ...he OFF mode i e the boiler has finished steaming the water has drained and flushed the drain LED is off Before auto descaling can commence a supply of dilute citric acid liquid must be connected from...

Page 15: ...anel 5 control cable or port 4 if use circuit board the steam generator can work normally check the control cable port and controller Something wrong with 1 indicator LED for water level is red check...

Page 16: ...rcial operators we recommend the use of a water softener All users commercial and domestic must ensure a regular maintenance routine for descaling the generator The frequency of this will vary accordi...

Page 17: ...ators are guaranteed for 12 months from the date of purchase This guarantee excludes consumable items such as the electrical elements and failures resulting from misuse or abuse such as a failure to d...

Reviews: