Aqua OC-105B User Manual Download Page 6

SG-B SERIES                                                                                                                                    STEAM GENERATOR 

  6                                                                                                                                                          E005-28-10-12   

 

 

Increase button   

 

Decrease button 

 

Dual  function  button  switches  a  fan  on  and  off  also  used  to  confirm 
changes in temperature settings.

   

Time 

display 

window 

Display the resting and operating time of the steam generator 

Temp 

display 

window 

Display the detected temperature of steam room   

10 

Light LED 

Indicator LED for the lamp of steam room .it is on/off with the on/off of 
the lamp in steam room 

11 

Water LED 

Indicator  LED for water level .red means water is filling. green means 
water level arrived control point.note:if the LED always in red (exceed 5 
minutes).check water supply and if water level valve is block .otherwise 
the water level inlet valve will be broken . 

12 

Drain LED 

Indicator LED for draining 

 shows red for manual draining and green for 

automatic draining at the end of the cycle.   

13 

Mode LED 

Shows  red  is  for  steam  on  demand  mode  and  green  for  conventional 
timing. 

14 

Heating LED 

Green  indicates  heating  is  on,  red  indicates  the  required  temperature 
has been reached and the heating has stopped 

15 

Overheat LED 

Indicator LED for over heat ,red means the steam generator was cut off 
as  the  heat  element  is  too  hot  (lack  of  water  ,the  heat  elements  may 
worked in air)     

 

16 

Fan LED 

Indicator LED for Fan the lamp of steam room .it is on/off with the on/off 
of the lamp in steam room 

17 

Clean LED 

Indicator LED shows descaling in operation. 

Remarks :    Please note for the generator to operate in steam on demand mode the steam on demand 
button must be connected. 
 
        (3)

OC-S Steam on demand switch 

The  steam  on  demand  switch  can  be  located  inside  or  outside  of  the  steam  room  then  connected  to  the 
controller. 
When the switch is operated the LED indicator inside the switch shows red and steam will be generated for 

30 minutes. At the end of 30 minutes or if the switch is operated again, the light will go out and the steam 
will stop.     

        (4)

commercial mode instruction(OC-B+OC-S )   

If  OC-B  is  under  domestic  model,  only  OC-B  control  the  steam  generator  .OC-S  doesn

t  work.  When 

OC-B  enter  commercial  model,  The  steam  generator  is  under  waiting  status  (the  time  window  shows 

Long

 and on circuit board the LED is flashing) , press OC-S it will operate steam generator , every press 

will  make the steam  generator keep  on working for 30 minutes , the temperature control will rely  on the 
OC-B controller

s setting before enter commercial model   

 

Summary of Contents for OC-105B

Page 1: ......

Page 2: ...solator This equipment must be installed by a competent person Disconnect the power supply before exposing electrical connections Confirm the right voltage to your steam generator 1 or 3 phase SAFETY...

Page 3: ...7 530 230 460 SG 180B O C 180B 18 0 230 400 1 3 78 0 26 1 530 230 460 Remarks if greater power is required one OC B controller may be used to control two or more steam generators e g if you need a 30K...

Page 4: ...the time widow displays Long the generator will operate continuously until it is switched off OC S 30 60 60 Steam on demand switch press once it will work 30 minutes press again it stop works special...

Page 5: ...12MPa 10 Overheat switch Boil dry protector operates at 110 11 Main circuit board Control center 12 Accessorial circuit board Connect and control the heat element 13 terminal Connection for power supp...

Page 6: ...r LED for over heat red means the steam generator was cut off as the heat element is too hot lack of water the heat elements may worked in air 16 Fan LED Indicator LED for Fan the lamp of steam room i...

Page 7: ...re that the track of the pipe does not create a trap into which condensate would gather and cause a blockage I e the pipe must not go down and then up There must be no valve or other blockage in the s...

Page 8: ...the power requirement The following table is given as a guide ambient air temperatures and frequency of use number of door openings can also affect the power requirements Installation The steam genera...

Page 9: ...e steam nozzle should be installed in the place which is far from the seat 300 overheat switch Fig 8 d Connect the drain outlet to a suitable drain via a copper pipe with the appropriate fittings e Ma...

Page 10: ...in place and then connect to the wire from the controller temperature sensor 4 scr ew Fig 10 Installation for power supply and control cable Confirm the correct voltage of power supply and wires Remov...

Page 11: ...in On RED D5 Liquid Inlet On RED D4 Reserve1ON RED D3 Light On RED D2 D1 RED Fan On LED COLOR KEY Fig 11 Tank H2 H1 V DC5V Switch C F 4 4 2 7 12Kw Steam Generator Circuit Diagram 2 JP1 OC S Controller...

Page 12: ...ve the knock out for the control cable entry and use a rubber grommet to protect the cable connect the cable to the relevant port on circuit board Ensure the power supply wire and control cable remain...

Page 13: ...display counts down to show the remaining time when it reaches 0 the steam generator will stop heating 8 Once the steam generator has operated for 10 minutes or more when it is turned off manually or...

Page 14: ...he OFF mode i e the boiler has finished steaming the water has drained and flushed the drain LED is off Before auto descaling can commence a supply of dilute citric acid liquid must be connected from...

Page 15: ...anel 5 control cable or port 4 if use circuit board the steam generator can work normally check the control cable port and controller Something wrong with 1 indicator LED for water level is red check...

Page 16: ...rcial operators we recommend the use of a water softener All users commercial and domestic must ensure a regular maintenance routine for descaling the generator The frequency of this will vary accordi...

Page 17: ...ators are guaranteed for 12 months from the date of purchase This guarantee excludes consumable items such as the electrical elements and failures resulting from misuse or abuse such as a failure to d...

Reviews: