12 Legend First Stage Service Manual
Table 1 - Troubleshooting Guide
SYMPTOM
POSSIBLE CAUSE
TREATMENT
Leakage or freeflow from second stage
1. High first-stage intermediate pres-
sure. (should be 135±5 psi)
1. Refer to first-stage Troubleshoot-
ing Guide.
2. LP seat (26) damaged or worn.
2. Replace LP seat.
3. Crown (21) adjusted incorrectly, lever
set too high
3. Reset crown preliminary set-
tings, and repeat Adjustment
Procedures.
4. Lever (25) bent
4. Replace lever.
5. Crown (21) sealing surface dam-
aged.
5. Replace crown.
6. Poppet spring (11) damaged.
6. Replace spring.
Low purge or excessive work of breath-
ing (full cylinder)
1. Low first-stage intermediate pres-
sure. (should be 135±5 psi)
1. Refer to first-stage Troubleshoot-
ing Guide.
2. Crown (21) adjusted incorrectly, lever
set too low.
2. Reset crown to preliminary
settings and repeat Adjustment
Procedures
.
3. Intermediate pressure hose (40)
clogged or obstructed.
3. Clean or replace hose.
4. Lever (25) bent
4. Replace lever.
Water entering second-stage
1. Hole in mouthpiece (12).
1. Replace mouthpiece.
2. Demand diaphragm (7) damaged.
2. Replace diaphragm.
3. Exhaust valve (13) damaged.
3. Replace valve.
4. Venturi lever o-ring (16) dirty, dam-
aged, or worn.
4. Disassemble and replace o-ring.
5. Diaphragm improperly seated be-
tween box bottom (29) and sealing
ring (5).
5. Remove front cover (3) and
properly reassemble sealing
ring with diaphragm (check for
distortion).
6. Box bottom damaged. (Check ex-
haust valve sealing surface.)
6. Disassemble and replace box
bottom
7. Inlet o-ring (17) damaged.
7. Replace o-ring.
8. Valve spindle o-ring (20) worn or
damaged
8. Replace o-ring.