15.    While holding the rim of the box bottom at eye level, turn 

the adjustable crown orifice in (clockwise) until the lever 
drops about 4mm below the case rim. Then, turn the 
crown counterclockwise until the lever is even with the 
case rim.

16.    Add a new o-ring (42) to the male end of the medium 

pressure hose. Install a new, lubricated o-ring (38) to the 
swivel end of the hose

17.    Adjust the lever height 

         

NOTE

: The inline adjustment tool can be use 

with crowns with a screwdriver slot or a hex hole. 
Make sure the inline tool is set to use the screw-
driver slot.

a.      Attach the Aqua 

Lung in-line tool 
(p/n 100190) to the 
second stage. It can 
accommodate both 
the crown orifice 
with the 5mm hex 
and the crown orifice with the slot. The tool is 
shown with the optional in-line medium pressure 
gauge (p/n111605). 

b.      Attach the swivel end of the medium pressure 

hose to the other end of the inline tool. Attach the 
male end of the hose to a properly adjusted first-
stage regulator (135±5). Attach the first-stage to 
a fully charged cylinder. Slowly open the cylinder 
valve to pressurize the regulator.

c.      Press inward on the adjustment wheel of the inline 

tool. Slowly rotate the adjustment wheel until the 
inline tool engages the crown orifice. Turn the 
crown in until the lever drops approximately 

¹₄

”. 

This will “coin” the rubber seat to help achieve a 
better seal. Now back the crown orifice out (coun-
terclockwise). The lever will raise. Continue until 
the lever is even with the rim of the box bottom.

18.    Position the diaphragm (7) into the box bottom. Using 

your finger or a small wooden dowel, work the edges 
of the diaphragm into place. Place the thin, white thrust 
washer (6) on top of the diaphragm. Make sure it is 
seated evenly all the way around.

19.    Screw in the diaphragm 

retainer (5), flat side fac-
ing the diaphragm, until 
fingertight. Use the Titan 
LX diaphragm retain-
ing tool (p/n 129001) to 
tighten approximately 
another 

¹₄

 turn. After 

installing the diaphragm 
retainer, grab the edges of the strike plate and gently tug 
the diaphragm to the left, right, top and bottom to make 
sure it is secure in the box bottom. If the diaphragm pulls 
out, then you need to reinstall it.

20.    Position the rubber purge cover (4) onto the box bottom. 

Make sure that the nameplate is oriented correctly.  In-
stall the mating ring (2) onto the retaining ring (1). While 
holding the purge cover stationary, screw the retaining 
ring  into the box bottom until snug.

F

Summary of Contents for Legend LX Second Stage

Page 1: ...LEGEND LX SECOND STAGE Copyright 2000 Aqua Lung America Inc Rev 7 2002 Authorized Technician TECHNICAL MAINTENANCE MANUAL ...

Page 2: ...TESTING 10 Second Stage Opening Effort Test 10 Second Stage Air Flow Test 10 Second Stage Purge Flow Test 10 External Leak Test 10 Subjective Breathing Test 10 TABLE 1 FIRST STAGE TROUBLSHOOTING GUIDE 12 TABLE 2 RECOMMENDED TOOL LIST 13 TABLE 3 RECOMMENDED LUBRICANTS AND CLEANERS 14 PROCEDURE A CLEANING AND LUBRICATION 15 TABLE 4 TORQUE SPECIFICATIONS 16 TABLE 5 TEST BENCH SPECIFICATIONS 16 LEGEND...

Page 3: ...leakage 2 Checking for stable intermediate pressure that is within the acceptable range 3 Checking for opening effort that is within the acceptable range 4 Checking for smooth operation of the control knob and venturi switch 5 A visual inspection of the filter for debris or discoloration 6 A visual inspection of the exhaust valve to see that it is in good shape and that it s resting against a clea...

Page 4: ...ool at protrusion to remove 5 Numbers in parentheses reference the key numbers on the exploded parts schematics For example in the state ment remove the o ring 20 from the the number 20 is the key number to the crown o ring DISASSEMBLY PROCEDURES Note Before performing any disassembly refer to the exploded parts drawing which references all mandatory replacement parts These parts should be replace...

Page 5: ... assembly out of the box bottom 9 Remove the valve body o ring 17 that will probably be left behind in the left side of the box bottom as you look at it 7 Grasp the venturi lever 19 and pull it out of the box bot tom Remove the o ring 18 from the venturi lever NOTE The venturi lever may have come out with the valve body in step 6 If this is the case depress the lever and slide the lever off from r...

Page 6: ...mpletely unscrew from the valve body Insert the pin end of the seat extractor tool pn 109436 into the valve body grasp the pin and pull the crown completely out of the valve body Remove the o ring 20 from the crown 17 Fold back the edges of the exhaust valve 13 and inspect underneath The seating surface should be clean and free of damage Inspect the exhaust valve It should be supple and have well ...

Page 7: ...t the lever is on the same side as the small dimple on the valve body and the outlet port is pointing to the right as the threaded inlet side faces away from you 6 With the feet of the shuttle valve pointing downward away from the lever and the lever pointing straight up perpendicular to the valve body insert the valve as sembly into the valve body Using your finger press the shuttle valve assembl...

Page 8: ...ed o ring 18 onto the venturi lever 19 Point the venturi lever upward and insert it into the box bottom Press it against the box bottom so the o ring is captured 12 While depressing the lever insert the valve body through the venturi lever and into the box bottom Be sure that the two index flats and the two lever feet engage the tabs molded into the box bottom 13 Slide a new lubricated o ring 17 d...

Page 9: ...e adjustment wheel of the inline tool Slowly rotate the adjustment wheel until the inline tool engages the crown orifice Turn the crown in until the lever drops approximately This will coin the rubber seat to help achieve a better seal Now back the crown orifice out coun terclockwise The lever will raise Continue until the lever is even with the rim of the box bottom 18 Position the diaphragm 7 in...

Page 10: ...n order to correct the problem s NOTE Extremely small leaks may be better detected by applying a soap solution or Snoop to the leak area Bubble streams will indicate the source of the leak Before disassembling to correct any leaks rinse the entire regulator thor oughly with fresh water and blow out all residual moisture with filtered low pressure 50 psi air Disassemble and remedy the problem refer...

Page 11: ...lation effort freeflow or flut tering of the second stage diaphragm When exhaling there should be no fluttering or sticking of the exhalation valve If any of these problems occur refer to Table 1 Troubleshooting This Ends Reassembly ...

Page 12: ...st stage Troubleshoot ing Guide 2 Crown 21 adjusted incorrectly lever set too low 2 Reset crown to preliminary settings and repeat Adjustment Procedures 3 Intermediate pressure hose 40 clogged or obstructed 3 Clean or replace hose 4 Lever 25 bent 4 Replace lever Water entering second stage 1 Hole in mouthpiece 12 1 Replace mouthpiece 2 Demand diaphragm 7 damaged 2 Replace diaphragm 3 Exhaust valve...

Page 13: ...ring removal and installation 109436 Seat extract install tool Crown removal and installation 100190 Inline Adjustment Tool 2nd stage adjustment n a Torque wrench inch pound Retaining nut hose n a 11 16 crows foot Retaining nut hose used with torque wrench n a Medium blade screwdriver Crown n a 11 16 wrench x2 Retaining nut hose n a 4mm hex wrench Adjustment Screw n a 1 16 wooden dowel Shuttle val...

Page 14: ...le stainless steel and brass parts Household grade Liquid dishwashing detergent diluted with warm water Degreaser for brass and stainless steel parts general cleaning solu tion for plastic and rubber Household grade CAUTION DO NOT use muriatic acid for the cleaning of any parts Muriatic acid even when strongly diluted can harm chrome plating and may leave a residue that is harmful to O ring seals ...

Page 15: ...tops dust caps etc may be soaked and cleaned in a solution of warm water mixed with mild dish soap Use only a soft nylon toothbrush to scrub away any deposits Rinse in fresh water and thoroughly blow dry using low pressure filtered air Hoses If buildup of corrosion is severe it is permissible to soak only the hose fittings in the ultrasonic cleaner as needed and not allow any solution to enter the...

Page 16: ...0 psig No leaks allowed Intermediate Pressure Inlet 2 500 3 000 100 psig 135 5 psi Intermediate Pressure Creep Inlet 2 500 3 000 100 psig 5 psi max between 5 to 15 seconds after cycling purging regulator Opening Effort Inlet 2 500 3 000 100 psig Intermediate pressure 135 5 psi 0 8 to 1 4 in H20 primary 1 1 to 1 7 in H2 0 Supreme Flow effort Intermediate pressure 135 5 psi 6 inches H20 maximum at 1...

Page 17: ...uthpiece Standard 13 129174 Exhaust Valve 14 104102 Exhaust Tee 15 AP2031 Retaining Nut 16 129148 Heat Exchanger 17 820015 O ring 18 AP1438 O ring 19 129138 Venturi Lever 20 820010 O ring 21 AP2033 Crown 22 820015 O ring 23 129146 Valve Body 24 AP1151 Pin 25 AP2035 Lever 26 AP2034 LP Seat 27 AP2036 Shuttle valve 28 AP2041 O ring 29 AP2021 Spring 30 AP2038 Counterbalance Chamber 31 129129 Adjustmen...

Page 18: ...2340 Cousteau Court Vista California 92083 www aqualung com Rev 7 2002 ...