background image

16

Service Schedule

To keep the Aqua Flo system operating properly, it is necessary to change the filters and sanitize the system periodically. 
Typically, this should be done on an annual basis.  Service frequency may vary depending on local water conditions.  High 
sediment, chlorine, turbidity, or hardness levels may require more frequent service. Use the following as a guide.

As needed

Clean the faucet with a soft cloth, avoid abrasive cleaners.

At least once in 6 months

Replace

 Stage 1

 Sediment Filter (41407001)

• 

Stage 2 & 4

 Carbon Block Filter (41407002)

At least once in 12 months

Replace
• 

Stage 3

 Ultrafiltration Membrane (41407005)

Sanitize the system*

 

Service and Maintenance

Rotate carbon block filters 3 months 
after changing  
(swap stage 2 & stage 4)

Kit Contents

1/4” Tubing

*Drinking Water 

System Sanitization 

Kit Preparation - 

42903016

Place some rags or a towel 
below the system as some 
water may leak during this 
procedure. Have a pail 
handy to drain water into.

1

  Shut off the water supply to the system  

 

at the adapter valve. Open the faucet  

 

and allow the system to drain completely  

 

Shut off the faucet once drained.

2

  Disconnect all 4 cartridges and replace  

 

them with the blank cartridges included  

 

in this kit. Disconnect the inlet line from  

 

the system 

 

and drain excess water  

 

into a pail.

4

  Using the tubing included in the kit, 

connect the sanitization cartridge between 
the adapter valve and the inlet 

 

 port on 

the system.

5

  Turn on the water at the adapter valve.  

 

 

If sanitizing an RO allow the system to fill the tank  

 

for 30 minutes. Next, turn on the faucet and    

 

allow the system to run for 30 minutes.

6

  Leaving the faucet open, shut off inlet  

 

water and let the system drain completely.

7

  Disconnect the sanitization cartridge from the  

 

inlet line and system. Reconnect the inlet line to  

 

the system and replace cartridges on system.

8

  Turn on the inlet water and check for leaks. If  

 

sanitizing an RO, allow the tank to fill for 30    

 

minutes and discard the first tank. Allow tank to  

 

refill for 30 minutes.

3

  Add either ½ teaspoon of household  

 

bleach or 1 packet of Sani-System Liquid  

 

Concentrate (#50036) to the clear  

 

sanitization cartridge and seal the    

 

cartridge tightly.

 

 

 

3 O-ring
Cartridge for
RO Systems

 

 

 

NOTE:

  if sanitizing an RO be sure to insert the 

blank RO cartridge (3 o-rings) in stage 3.

Your system is now clean and ready to use!

Summary of Contents for QCUF

Page 1: ...Installation Operation Service Instructions with Part List Quick Change Ultrafiltration Drinking Water System Models QCUF...

Page 2: ......

Page 3: ...lable when approved for printing Continuing design refinement could cause changes that may not be included in this publication WARNING If incorrectly installed operated or maintained this product can...

Page 4: ...nstallation Step 1 Select Component Installation Locations 10 Step 2 Faucet Installation 11 Step 3 Install T Adapter Valve on Water Supply 13 Step 4 Install Filter System Assembly 14 Step 5 Start Up 1...

Page 5: ...ter Stage 1 5 Micron Carbon Block Filter Stage 2 5 Micron Ultrafiltration Membrane Stage 3 0 2 Micron Carbon Block Filter Stage 4 5 Micron 15 8 2 0 4 7 14 3 Dimensions 2 5 13 1 Part Model Description...

Page 6: ...tridge Specifications The performance and life of an ultrafiltration membrane or filter element is highly dependent upon pressure temperature and water quality Part Description Purpose Micron Rating C...

Page 7: ...Utility Knife 2 Flathead Screwdriver 3 Phillips Screwdriver 4 Center Punch 5 7 8 Stepped Drill Bit 6 Finish Hole Saw 7 Porcelain Saw 8 1 8 3 8 Drill Bits 9 Heavy Duty Drill 10 Work Light 11 2 Adjustab...

Page 8: ...microscopic impurities Hollow fiber membranes utilize numerous long narrow porous filaments packed inside the housing Product water diffuses through the membrane while impurities become trapped in th...

Page 9: ...Hardware 7 T Adaptor 8 Locking Clip 3 8 9 3 8 Elbow 10 Faucet Adapter 11 Locking Clip 1 4 12 1 4 Elbow 13 4X 10 Phillips Self Tapping Screws 14 1 4 Tubing 4 ft 15 3 8 Tubing 4 ft 16 Installation Templ...

Page 10: ...anual covers the technical aspects of Aqua Flo Quick Change drinking water systems It is important to read this manual thoroughly so that you can properly apply install and service these systems The s...

Page 11: ...near a sink for easy access to cold water Lengths of 1 4 inch and 3 8 inch OD plastic tubing will be required to make this installation Evaluate the installation site to determine the easiest path for...

Page 12: ...It should be positioned so that water is dispensed over the sink A 7 8 diameter hole is required Important considerations Access to the bottom undersink of the faucet is required for attachment of pro...

Page 13: ...the porcelain speed may be increased After a complete ring has been cut through the porcelain change over to the metal cutter Avoid contacting the outer rim of cut porcelain when drilling CAUTION Avoi...

Page 14: ...sher metal base and large rubber washer above sink items 1 4 2 Install plastic washer lock washer and nut items 5 7 onto faucet stem below sink and tighten Be sure to properly align the faucet 3 Insta...

Page 15: ...13 Step 3 Install T Adapter Valve on Water Supply Part 60010643 T Adapter Cold Water Supply T Adapter To Sediment Filter...

Page 16: ...aving approximately a 1 2 space between the screw head and mounting surface 4 Hang the bracket on the mounting screws If unit is loose tighten the screws further Install Filter Cartridges 1 Twist the...

Page 17: ...correct the issue 4 Open faucet to flush carbon fines sanitization solution After allowing the system to run for 20 minutes turn off the faucet 5 System is ready to use WARNING Do not drink water pro...

Page 18: ...o drain completely Shut off the faucet once drained 2 Disconnect all 4 cartridges and replace them with the blank cartridges included in this kit Disconnect the inlet line from the system and drain ex...

Page 19: ...ange Sediment Filter Stage 1 1 2 4 41407002 Cartridge Quick Change Carbon Block Stage 2 4 2 3 41407005 Cartridge Quick Change Ultrafiltration Membrane Stage 3 1 5 Ci220808W Elbow 1 4 Stem 1 6 Ci221212...

Page 20: ...F W Tubing 1 4 4 5 PE 12 EI 0500F W Tubing 3 8 4 6 PiC1812R Locking Clip 3 8 2 7 PiC1808R Locking Clip 1 4 2 8 Ci221212W Elbow 3 8 x 3 8 2 9 Ci220808W Elbow 1 4 x 1 4 2 10 41407554 O Ring Small 11 414...

Page 21: ...above a All of 1 above b UF membrane worn out b Replace UF membrane 3 Bad tasting product water a Decrease in product quality see 2 above a Same as 2 above b Polishing filter exhausted b Replace polis...

Page 22: ...INCLUDING WITHOUT LIMITATION WARRANTIES OF MERCHANTABILITY AND FITNESS FOR PARTICULAR PURPOSE ARE LIMITED TO THE DURATION OF THE PERIOD SPECIFIED ABOVE FOR THE PARTS DESCRIBED IN THIS LIMITED WARRANTY...

Page 23: ...21...

Page 24: ...55026 2022 09 20 Canature WaterGroup 855 Park Street Unit 1 Regina SK S4N 6M1 Canada Toll Free 1 877 288 9888 USA Office 6353 Commerce Drive Whitestown IN 46075 USA Toll Free 1 877 288 9888...