background image

1

Safe Practices

Throughout this manual there are paragraphs set off by special headings.

NOTE:  

Note is used to emphasize installation, operation or maintenance information which is important, but does not 

present any hazard. Example:

NOTE: 

 

The nipple must extend no more than 1 inch above the cover plate.

Caution!:

  Caution is used when failure to follow directions could result in damage to equipment or property.  Example:

  

CAUTION!  

Disassembly while under water pressure can result in flooding. 

WARNING!: 

 Warning is used to indicate a hazard which could cause injury or death if ignored.  Example:

WARNING!  Electrical shock hazard! Unplug the unit before removing the timer mechanism or cover plates!

Serial Number

The serial number is located on the rear of the UF manifold housing. Record this number on the warranty page located at 
the end of this manual.

NOTE:

 

Do not remove or destroy the serial number. It must be referenced on requests for warranty repair or replacement.

This publication is based on information available when approved for printing. Continuing design refinement could cause 
changes that may not be included in this publication.

WARNING!  If incorrectly installed, operated or maintained, this product can cause severe injury. Those who 
install, operate, or maintain this product should be trained in its proper use, warned of its dangers, and should 
read the entire manual before attempting to install, operate or maintain this product.

Attention Aqua Flo Customer:

This system is intended for use on potable water supplies or disinfected water containing cysts. Do not use where water 
is microbiologically unsafe or with water of unknown quality. If bacterial  contamination is present, a recognized method 
of water disinfection is required.
Check with your public works department for applicable local plumbing and sanitation codes. Follow your local codes if 
they differ from the standards used in this manual.
The Aqua Flo Quick Change Drinking Water System contains a replaceable ultrafiltration membrane filter. The filtered 
water should be tested periodically to verify that the system is performing properly.

Serial Number Label

U - MM-DD-YY-XXXXXX

Date of 

manufacture

Serial

Code

Data
Plate
Label Containing
Model #

Summary of Contents for QCUF

Page 1: ...Installation Operation Service Instructions with Part List Quick Change Ultrafiltration Drinking Water System Models QCUF...

Page 2: ......

Page 3: ...lable when approved for printing Continuing design refinement could cause changes that may not be included in this publication WARNING If incorrectly installed operated or maintained this product can...

Page 4: ...nstallation Step 1 Select Component Installation Locations 10 Step 2 Faucet Installation 11 Step 3 Install T Adapter Valve on Water Supply 13 Step 4 Install Filter System Assembly 14 Step 5 Start Up 1...

Page 5: ...ter Stage 1 5 Micron Carbon Block Filter Stage 2 5 Micron Ultrafiltration Membrane Stage 3 0 2 Micron Carbon Block Filter Stage 4 5 Micron 15 8 2 0 4 7 14 3 Dimensions 2 5 13 1 Part Model Description...

Page 6: ...tridge Specifications The performance and life of an ultrafiltration membrane or filter element is highly dependent upon pressure temperature and water quality Part Description Purpose Micron Rating C...

Page 7: ...Utility Knife 2 Flathead Screwdriver 3 Phillips Screwdriver 4 Center Punch 5 7 8 Stepped Drill Bit 6 Finish Hole Saw 7 Porcelain Saw 8 1 8 3 8 Drill Bits 9 Heavy Duty Drill 10 Work Light 11 2 Adjustab...

Page 8: ...microscopic impurities Hollow fiber membranes utilize numerous long narrow porous filaments packed inside the housing Product water diffuses through the membrane while impurities become trapped in th...

Page 9: ...Hardware 7 T Adaptor 8 Locking Clip 3 8 9 3 8 Elbow 10 Faucet Adapter 11 Locking Clip 1 4 12 1 4 Elbow 13 4X 10 Phillips Self Tapping Screws 14 1 4 Tubing 4 ft 15 3 8 Tubing 4 ft 16 Installation Templ...

Page 10: ...anual covers the technical aspects of Aqua Flo Quick Change drinking water systems It is important to read this manual thoroughly so that you can properly apply install and service these systems The s...

Page 11: ...near a sink for easy access to cold water Lengths of 1 4 inch and 3 8 inch OD plastic tubing will be required to make this installation Evaluate the installation site to determine the easiest path for...

Page 12: ...It should be positioned so that water is dispensed over the sink A 7 8 diameter hole is required Important considerations Access to the bottom undersink of the faucet is required for attachment of pro...

Page 13: ...the porcelain speed may be increased After a complete ring has been cut through the porcelain change over to the metal cutter Avoid contacting the outer rim of cut porcelain when drilling CAUTION Avoi...

Page 14: ...sher metal base and large rubber washer above sink items 1 4 2 Install plastic washer lock washer and nut items 5 7 onto faucet stem below sink and tighten Be sure to properly align the faucet 3 Insta...

Page 15: ...13 Step 3 Install T Adapter Valve on Water Supply Part 60010643 T Adapter Cold Water Supply T Adapter To Sediment Filter...

Page 16: ...aving approximately a 1 2 space between the screw head and mounting surface 4 Hang the bracket on the mounting screws If unit is loose tighten the screws further Install Filter Cartridges 1 Twist the...

Page 17: ...correct the issue 4 Open faucet to flush carbon fines sanitization solution After allowing the system to run for 20 minutes turn off the faucet 5 System is ready to use WARNING Do not drink water pro...

Page 18: ...o drain completely Shut off the faucet once drained 2 Disconnect all 4 cartridges and replace them with the blank cartridges included in this kit Disconnect the inlet line from the system and drain ex...

Page 19: ...ange Sediment Filter Stage 1 1 2 4 41407002 Cartridge Quick Change Carbon Block Stage 2 4 2 3 41407005 Cartridge Quick Change Ultrafiltration Membrane Stage 3 1 5 Ci220808W Elbow 1 4 Stem 1 6 Ci221212...

Page 20: ...F W Tubing 1 4 4 5 PE 12 EI 0500F W Tubing 3 8 4 6 PiC1812R Locking Clip 3 8 2 7 PiC1808R Locking Clip 1 4 2 8 Ci221212W Elbow 3 8 x 3 8 2 9 Ci220808W Elbow 1 4 x 1 4 2 10 41407554 O Ring Small 11 414...

Page 21: ...above a All of 1 above b UF membrane worn out b Replace UF membrane 3 Bad tasting product water a Decrease in product quality see 2 above a Same as 2 above b Polishing filter exhausted b Replace polis...

Page 22: ...INCLUDING WITHOUT LIMITATION WARRANTIES OF MERCHANTABILITY AND FITNESS FOR PARTICULAR PURPOSE ARE LIMITED TO THE DURATION OF THE PERIOD SPECIFIED ABOVE FOR THE PARTS DESCRIBED IN THIS LIMITED WARRANTY...

Page 23: ...21...

Page 24: ...55026 2022 09 20 Canature WaterGroup 855 Park Street Unit 1 Regina SK S4N 6M1 Canada Toll Free 1 877 288 9888 USA Office 6353 Commerce Drive Whitestown IN 46075 USA Toll Free 1 877 288 9888...