background image

8

Tubing Connectors

The Aqua Flo system features reliable and convenient push-to-connect tubing connectors.  Tubing is easily connected and 
disconnected from these fittings as follows.

Connect: 

Cut the tubing squarely with a sharp knife. Be careful not to crush the tubing.  To 
avoid leaks, make sure the tubing end is smooth and free of burrs and abrasions. 
Lubricate the end of the tube with water or a light coat of silicone and push 
the tube end firmly into the fitting. You should feel it push past the O-ring. Avoid 
bending the tubing sharply away from the fitting.

Disconnect: 

Hold the collar against the fitting body and pull the tube from the fitting.

In the unlikely event that the connection leaks, remove and recut the tubing. 
Check the inside of the fitting for debris or O-ring damage. Reconnect.

Push-to-connect tubing connectors grip the outside diameter of the tube. To 
help assure a reliable connection, it is important to use high quality tubing with a 
consistent outside diameter.

Preparation

1.   Cut tube squarely with a sharp knife.

This manual covers the technical aspects of Aqua Flo Quick Change drinking water systems. It is important to read this 
manual thoroughly so that you can properly apply, install, and service these systems.
The substances reduced by this system are not necessarily in the customer’s untreated water. 

Warranty

A limited warranty is extended to the original end user from Canature WaterGroup. This warranty is printed on the back 
cover of the Owner’s Guide.

Application Guidelines

The Aqua Flo system is designed for use on potable water supplies meeting the guidelines outlined in Table 1. The system 
should be installed on a home’s cold water line. The flushing stream should discharge through an approved siphon break. 
Installation of this system must comply with state and local laws and regulations.

Package Content

The Aqua Flo system is shipped from the factory in carton:

NOTE:  

The filter elements are shipped in their own sealed packaging. This will help to simplify preparation of the system 

and to maximize the shelf life of the UF membrane element.

Product Information

Quick-Connect  Fit ting 

Insertion & Removal of Plastic or  

Copper Tubing
1. Simply 

push in 

tube to 

attach.

2.  Tube is secured in position.

3.  Push in collet from both sides to 

release tubing.

Summary of Contents for QCUF

Page 1: ...Installation Operation Service Instructions with Part List Quick Change Ultrafiltration Drinking Water System Models QCUF...

Page 2: ......

Page 3: ...lable when approved for printing Continuing design refinement could cause changes that may not be included in this publication WARNING If incorrectly installed operated or maintained this product can...

Page 4: ...nstallation Step 1 Select Component Installation Locations 10 Step 2 Faucet Installation 11 Step 3 Install T Adapter Valve on Water Supply 13 Step 4 Install Filter System Assembly 14 Step 5 Start Up 1...

Page 5: ...ter Stage 1 5 Micron Carbon Block Filter Stage 2 5 Micron Ultrafiltration Membrane Stage 3 0 2 Micron Carbon Block Filter Stage 4 5 Micron 15 8 2 0 4 7 14 3 Dimensions 2 5 13 1 Part Model Description...

Page 6: ...tridge Specifications The performance and life of an ultrafiltration membrane or filter element is highly dependent upon pressure temperature and water quality Part Description Purpose Micron Rating C...

Page 7: ...Utility Knife 2 Flathead Screwdriver 3 Phillips Screwdriver 4 Center Punch 5 7 8 Stepped Drill Bit 6 Finish Hole Saw 7 Porcelain Saw 8 1 8 3 8 Drill Bits 9 Heavy Duty Drill 10 Work Light 11 2 Adjustab...

Page 8: ...microscopic impurities Hollow fiber membranes utilize numerous long narrow porous filaments packed inside the housing Product water diffuses through the membrane while impurities become trapped in th...

Page 9: ...Hardware 7 T Adaptor 8 Locking Clip 3 8 9 3 8 Elbow 10 Faucet Adapter 11 Locking Clip 1 4 12 1 4 Elbow 13 4X 10 Phillips Self Tapping Screws 14 1 4 Tubing 4 ft 15 3 8 Tubing 4 ft 16 Installation Templ...

Page 10: ...anual covers the technical aspects of Aqua Flo Quick Change drinking water systems It is important to read this manual thoroughly so that you can properly apply install and service these systems The s...

Page 11: ...near a sink for easy access to cold water Lengths of 1 4 inch and 3 8 inch OD plastic tubing will be required to make this installation Evaluate the installation site to determine the easiest path for...

Page 12: ...It should be positioned so that water is dispensed over the sink A 7 8 diameter hole is required Important considerations Access to the bottom undersink of the faucet is required for attachment of pro...

Page 13: ...the porcelain speed may be increased After a complete ring has been cut through the porcelain change over to the metal cutter Avoid contacting the outer rim of cut porcelain when drilling CAUTION Avoi...

Page 14: ...sher metal base and large rubber washer above sink items 1 4 2 Install plastic washer lock washer and nut items 5 7 onto faucet stem below sink and tighten Be sure to properly align the faucet 3 Insta...

Page 15: ...13 Step 3 Install T Adapter Valve on Water Supply Part 60010643 T Adapter Cold Water Supply T Adapter To Sediment Filter...

Page 16: ...aving approximately a 1 2 space between the screw head and mounting surface 4 Hang the bracket on the mounting screws If unit is loose tighten the screws further Install Filter Cartridges 1 Twist the...

Page 17: ...correct the issue 4 Open faucet to flush carbon fines sanitization solution After allowing the system to run for 20 minutes turn off the faucet 5 System is ready to use WARNING Do not drink water pro...

Page 18: ...o drain completely Shut off the faucet once drained 2 Disconnect all 4 cartridges and replace them with the blank cartridges included in this kit Disconnect the inlet line from the system and drain ex...

Page 19: ...ange Sediment Filter Stage 1 1 2 4 41407002 Cartridge Quick Change Carbon Block Stage 2 4 2 3 41407005 Cartridge Quick Change Ultrafiltration Membrane Stage 3 1 5 Ci220808W Elbow 1 4 Stem 1 6 Ci221212...

Page 20: ...F W Tubing 1 4 4 5 PE 12 EI 0500F W Tubing 3 8 4 6 PiC1812R Locking Clip 3 8 2 7 PiC1808R Locking Clip 1 4 2 8 Ci221212W Elbow 3 8 x 3 8 2 9 Ci220808W Elbow 1 4 x 1 4 2 10 41407554 O Ring Small 11 414...

Page 21: ...above a All of 1 above b UF membrane worn out b Replace UF membrane 3 Bad tasting product water a Decrease in product quality see 2 above a Same as 2 above b Polishing filter exhausted b Replace polis...