Using the proper method, u:lize primer and cement to connect the PVC parts in the following manner:
A. Lay the tees end-to-end with the 1” tee outlet poin:ng the same direc:on.
B. Aoach each reducer to the side if the tee facing the other tee.
C. Aoach the sec:on of PVC pipe into each reducer. Make certain the 1” outlet of each tee point
in the same direc:on.
D. TURN POOL OFF.
E. Hold this sec:on along the return line to determine where to cut and leave enough pipe
surfaces at each cuvng point to properly aoach into each tee. When aoaching the bypass
make certain the 1” tee outlets will be facing the direc:on where the sani:zer and de-
chlorinator will be posi:oned.
F. Aoach each 1” spa hose to the 1” tee outlet. (Note: the spa hose have a curve to it. Aoach to
where the curve works toward connec:ng to the system.)
G. Separate one 1” PVC assembly (Threaded male & female) and aoach the male end to the end
of one spa hose and the female to the end of the second hose.
IMPORTANT: Incorrect plumbing installa:on will damage the system!
When
plumbing permanent placement or using the winterizing disconnect type system, the
tee CLOSEST TO THE POOL FILTER SHOULD LEAD TO THE ATTACHMENT ON THE
“UPFLOW INLET” SIDE, OR RIGHT SIDE, WHEN FACING BOTH PORTALS OF THE BYPASS.
This flow paoern is required for water to enter the “UPFLOW INLET” PORTAL.
WARNING!
DO NOT CONNECT TO THE PORTAL SIDE OF THE ASSEMBLY WHICH READS
“DOWNFLOW INLET” CONNECTING THE PORTALS OTHER THAN AS INSTRUCTED WILL
PACK THE MEDIA, and, IF ALLOWED TO RUN INCORRECTLY FOR AN EXTENDED PERIOD
OF TIME WILL DAMAGE THE UNIT AND VOID THE WARRANTY.
H. Separate the second 1” PVC union and aoach the piece to the gray pipe 90 degree fivng that
connects to the “UPFLOW INLET” to the union piece that will mate to the union piece
extending from the hose connected to the first, or upstream, tee closest to the pool filter.
I. Then connect the remaining union piece to the gray pipe fivng that leads from the
“DOWNFLOW INLET” and connect it to the ma:ng union piece located at the downstream
union. The bypass reduc:on will force water to flow through the sani:zer and de-chlorinator
in the required flow paoern.
J. Disconnect or unscrew union fivngs then connect the fivngs located at the end of each hose
to each other to make certain they will connect when the system is winterized. Aoaching the
system in this way will keep the unit from being incorrectly aoached in the future.
K. Make certain red flow indicator arrows are posi:oned to flow water into the “UPFLOW INLET”.
L. Flush system prior to using on the pool. (see flushing instruc:ons)
M. Aner properly flushing aoach to the pool, turn system on and then check for leaks.
12