51
NOTE: “1” is upper position and “0” is bottom position.
Dip 1
Dip 2 Dip 3 Dip 4 Group address
1: RS485
baud
rate=9600
Restart to
take effect
0
0
0
Single group only. It’s required to set up master battery with this
setting and slave batteries are unrestricted.
1
0
0
Multiple group condition. It’s required to set up master battery on the
first group with this setting and slave batteries are unrestricted.
0
1
0
Multiple group condition. It’s required to set up master battery on the
second group with this setting and slave batteries are unrestricted.
1
1
0
Multiple group condition. It’s required to set up master battery on the
third group with this setting and slave batteries are unrestricted.
0
0
1
Multiple group condition. It’s required to set up master battery on the
fourth group with this setting and slave batteries are unrestricted.
1
0
1
Multiple group condition. It’s required to set up master battery on the
fifth group with this setting and slave batteries are unrestricted.
NOTE: The maximum groups of lithium battery is 5 and for maximum number for each group, please check
with battery manufacturer.
3.
Installation and Operation
After configuration, please install LCD panel with inverter and Lithium battery with the following steps.
LIO 4805/4810
Step 1. Use custom-made RJ45 cable to connect inverter and Lithium battery.
Rack type
Wall mounted type