46
Table 2 Inverter Mode Specifications
MODEL
3.2KW
Rated Output Power
3200W
Output Voltage Waveform
Pure Sine Wave
Output Voltage Regulation
230Vac± 5%
Output Frequency
60Hz or 50Hz
Peak Efficiency
93%
Overload Protection
5s@≥130% load; 10s@105%~130% load
Surge Capacity
2* rated power for 5 seconds
Low DC Warning Voltage
23.0Vdc
22.0Vdc
@ load < 50%
@ load ≥ 50%
Low DC Warning Return Voltage
23.5Vdc
23.0Vdc
@ load < 50%
@ load ≥ 50%
Low DC Cut-off Voltage
21.5Vdc
21.0Vdc
@ load < 50%
@ load ≥ 50%
High DC Recovery Voltage
32Vdc
High DC Cut-off Voltage
33Vdc
DC Voltage Accuracy
+/-0.3V@ no load
THDV
<5% for linear load,<10% for non-linear load @ nominal voltage
DC Offset
≦
100mV
No Load Power Consumption
<40W