![APT VEYRON IV 3.2KW User Manual Download Page 20](http://html1.mh-extra.com/html/apt/veyron-iv-3-2kw/veyron-iv-3-2kw_user-manual_2957020020.webp)
18
05
Battery type
LIb-protocol compatible battery
Select “LIb” if using Lithium
battery compatible to Lib
protocol. If selected,
programs of 02, 26, 27 and
29 will be automatically set
up. No need for further
setting.
3
rd
party Lithium battery
If selected, programs of 02,
26, 27 and 29 will be
automatically set up. No need
for further setting. Please
contact the battery supplier
for installation procedure.
ISC
If selected, setting value in
program 26 is 28V, program
27 is 27V and program 29 is
21V.
06
Auto restart when overload
occurs
Restart disable (default)
Restart enable
07
Auto restart when over
temperature occurs
Restart disable (default)
Restart enable
09
Output frequency
50Hz (default)
60Hz
10
Output voltage
220V
230V (default)