background image

HYDRAULIC  OPERATOR  TWENTY

ENGLISH

INSTALLING SYSTEM  PRELIMINARY CHECKS OF THE GATE

HYDRAULIC OPERATOR INSTALLATION

 

For a correct operating gate must satisfy the following conditions:
- robust and rigid structure of the leaves;
- the leaf movement should be smooth and uniform but without
any friction during the race;
- the hinges must be in excellent state;
- limit mechanical stops placed.

Any metalwork shall be conducted before installation of automation.
The state of the gate structure influence the reliability and safety of the automatism.

A) Attach the rear mounting on the pillar and follow the signs of Tables A and B, modify, if necessary, the length of 
the attack (fig. 1).
Compliance with the dimensions shown in the above tables to ensure the smooth operation of the automatism.
In the case of an iron pillar carefully weld the rear mounting directly on the pier.
In the case of masonry opt for one of the following solutions:

1) Cash suitably a plate to wall, and then pay back the attack;
2) Fix to the pillar, with screws and dowel, the rear mounting plate and weld the rear mounting plate
(Fig. 2);

B) Attach the operator to the rear (Fig. 2);

Release the hydraulic operator

E) Install the front end on the stroke (Fig. 4);
F) Close the door of the gate and, keeping the operator in perfectly level position, locate the position of a front on 
the wing (Fig. 5);
G) Temporarily fasten the front attachment on the gate by two spot welds (protect the stroke from any welding 
slag fig.6);
H) Release the hydraulic operator, make sure the gate is open and free to stay on the mechanical stops to limit 
pre-installed and verify that the movement of the gate is smooth and without
friction;
I) Remove the operator from its temporarily and permanently weld the front attachment on the wing(Fig. 7);
L) Attach the cover rod hydraulic operator (Fig. 7);
M) Re-lock the hydraulic operator and to effectue the electrical connections with the electronic equipment, 
according to the instructions in the manual.

C)

;

D) Extract the chrome rod until total joke and bring it within approximately 5 mm (Fig. 3), screw in half the front 

fitting (joint head) on the stem and tighten with the supplied nut (fig. 3.1);

1) Hydraulic operators
2) Photocells
3) Electronic control box
4) Key selector

5) Receiver
6) Flashing light
7) Electric lock

You needs always to separate the connecting cables
of the low voltage accessories from the 230 V.
Use separate sheaths to avoid any type of interference.

Connect power cables hydraulic operator:
- Co (Common) = gray cable
- Ap (open) = brown cable
- Ch (closing) = black cable
- T (earth) = yellow / green

11

Summary of Contents for TWENTY 270 B

Page 1: ...onnement et une longue dur e de vie du produit At fin d viter des op rations incorrectes et de ne pas risquer des accidents s rieux lire attentivement ce manuel et respecter scrupuleusement les inform...

Page 2: ...iferimenti normativi emergenza e consegnare all utilizzatore dell impianto la nazionali per ottenere un livello di sicurezza adeguato Guida per l Utente allegata al prodotto devono essere seguite le N...

Page 3: ...o Oil Huile Aceite Blocco anta Swing lock Blocage portail Bloqueo hoja Rallentamento corsa idraulico Hydraulic slowdown Rallentissement hidraulique Parada suave hidraulico Portata pompa Pump capacity...

Page 4: ...attacco posteriore fig 2 C Sbloccare l attuatore oleodinamico con la chiave di sblocco in dotazione D Estrarre lo stelo cromato fino a totale battuta e farlo rientrare di circa 5 mm fig 3 avvitare a m...

Page 5: ...io effettuare una nicchia sul pilastro fig 2 1 La quota A deve essere sempre maggiore della quota E Piastra a murare Attacco Fig 2 Fig 2 1 c La corsa dello stelo inferiore alla corsa massima al fine d...

Page 6: ...ATTUATORE OLEODINAMICO TWENTY ITALIANO FISSAGGIO SUPPORTO ANTERIORE Attacco anteriore TWENTY 270 Fig 3 Fig 5 Fig 6 Fig 7 Fig 4 Fig 3 1 FISSAGGIO CARTER COPRI STELO 6...

Page 7: ...clusivamente da personale specializzato possibilmente autorizzatoAprimatic Utilizzare ricambi originaliAprimatic RIPARAZIONE INDIVIDUAZIONE GUASTI Il cancello non si muove controllo alimentazione elet...

Page 8: ...cco idraulico non necessitano di installare l elettroserratura garantendo il blocco meccanico dell anta quando il motore non in funzione Gli altri modelli senza blocco idraulico necessitano di una o p...

Page 9: ...the product 8 The mechanical parts must conform to the provisions of 21 Do not allow children or adults to stay near the product Standards EN 12604 and EN 12605 while it is operating 9 Manufacturer is...

Page 10: ...sa idraulico Hydraulic slowdown Rallentissement hidraulique Parada suave hidraulico Portata pompa Pump capacity Capacit pompe C bomba apacidad TWENTY 270 SF TWENTY 270 C TWENTY 270 B 1400 1400 1400 1...

Page 11: ...e front end on the stroke Fig 4 F Close the door of the gate and keeping the operator in perfectly level position locate the position of a front on the wing Fig 5 G Temporarily fasten the front attach...

Page 12: ...e a niche on the pillar Fig 2 1 the dimension A must be always greater than the distance E Plate to wall Plate attack Fig 2 Fig 2 1 c The stroke of the rod is less than the maximum stroke in order to...

Page 13: ...HYDRAULIC OPERATOR TWENTY ENGLISH Fig 3 Fig 5 Fig 6 Fig 7 Fig 4 Fig 3 1 FIXING CARTER COVER ROD FIXING FRONT SUPPOR Attacco anteriore TWENTY 270 13...

Page 14: ...check the proper adjustment of the anti crushing safety valve regulating power and efficiency of the release system The possible reparations on the automation must be effected exclusively from special...

Page 15: ...proceed to release maneuver as follows To open the cork of protection and to insert the key in endowment Turn the key counterclockwise to unlock Turn the key clockwise to lock Make the opening or clo...

Page 16: ...cientes a la CEE adem s de otros generadores de impulsos para evitar que el equipo respetarse las normativas nacionales para obtener un autom tico sea accionado involuntariamente nivel de seguridad ad...

Page 17: ...namento Operating temperature Temperature de funtionement Temperatura ambiente Peso Weight Poid Peso Olio Oil Huile Aceite Blocco anta Swing lock Blocage portail Bloqueo hoja Rallentamento corsa idrau...

Page 18: ...on tornillos y tacos la placa empalme posterior y luego suelde atentamente el empalme posterior en la placa tal y como se indica en la fig 2 B Fije el operador en el empalme posterior por medio de los...

Page 19: ...a deseada efectuar un hueco en el pilar fig 2 1 La cota A siempre debe ser mayor que la cota E Placa de muro Empalme Fig 2 Fig 2 1 ngulo de abertura c La carrera del vastago es menor de la carrera max...

Page 20: ...FIJACI N SOPORTE DELANTERO Ataque delantero TWENTY Fig 3 Fig 5 Fig 6 Fig 7 Fig 4 Fig 3 1 FIJACI N CARTER VASTAGO ESPA OL ACCI NADORES HIDRAULICOS TWENTY 20...

Page 21: ...equipo Para volver a bloquear el operador gire la llave en sentido horario hasta que se detenga Saque la llave y cierre el tap n de protecci n Reconecte l alimentaci n electrica de l automatismos MANT...

Page 22: ...desbloqueo MANUAL PARA EL USUARIO FUNCIONAMIENTO MANUAL Si fuera necesario mover la cancela manualmente por ejemplo por un corte de corriente o un fallo de la automaci n es necesario abrir temporalme...

Page 23: ...23...

Page 24: ...Aprimatic s r l Via Emilia 147 40064 Ozzano dell Emilia Bologna www aprimatic it info aprimatic it...

Reviews: