If shorted to positive: excessive voltage has been detected at PIN 28 of the ENGINE con-
nector. If the circuit is open, shorted to negative: voltage equal to zero has been detected
at PIN 28 of the ENGINE connector.
Troubleshooting
•
If shorted to positive: disconnect the coil connector, set the key to ON, activate the coil with
Navigator and check voltage at connector PIN 28: if there is voltage, restore the cable har-
ness; if voltage = 0, replace the coil.
•
If the circuit is open, shorted to negative: check electric characteristics of the coil: if not OK,
replace the coil, if OK check the coil connector and the Marelli control unit connector; if not
OK, restore, if OK, check cable continuity between the two cable terminals: if there is not
continuity, restore the cable harness; if there is cable continuity, with key set to ON, check
the ground insulation of the cable (from coil connector or control unit connector), if not OK,
restore cable harness.
Coil 2 P0352
•
shorted to positive / shorted to negative, open circuit.
Error cause
•
If shorted to positive: excessive voltage has been detected at PIN 27 of the ENGINE con-
nector. If the circuit is open, shorted to negative: voltage equal to zero has been detected
at PIN 27 of the ENGINE connector
Troubleshooting
•
If shorted to positive: disconnect the coil connector, set the key to ON, activate the coil with
Navigator and check voltage at connector PIN 27: if there is voltage, restore the cable har-
ness; if voltage = 0, replace the coil.
•
If the circuit is open, shorted to negative: check electric characteristics of the coil: if not OK,
replace the coil, if OK check the coil connector and the Marelli control unit connector; if not
OK, restore, if OK, check cable continuity between the two cable terminals: if there is not
continuity, restore the cable harness; if there is cable continuity, with key set to ON, check
the ground insulation of the cable (from coil connector or control unit connector), if not OK,
restore cable harness.
Coil 3 P0353
•
shorted to positive / shorted to negative, open circuit.
Error cause
•
If shorted to positive: excessive voltage has been detected at PIN 2 of the ENGINE con-
nector. If the circuit is open, shorted to negative: voltage equal to zero has been detected
at PIN 2 of the ENGINE connector.
Troubleshooting
Electrical system
TUONO V4 R
ELE SYS - 176
Summary of Contents for TUONO V4 R 2010
Page 1: ...SERVICE STATION MANUAL B043120 TUONO V4 R ...
Page 4: ......
Page 6: ...INDEX OF TOPICS CHARACTERISTICS CHAR ...
Page 51: ...INDEX OF TOPICS SPECIAL TOOLS S TOOLS ...
Page 59: ...INDEX OF TOPICS MAINTENANCE MAIN ...
Page 81: ...INDEX OF TOPICS TROUBLESHOOTING TROUBL ...
Page 90: ...INDEX OF TOPICS ELECTRICAL SYSTEM ELE SYS ...
Page 107: ...TABLE C2 DEMAND SENSOR 1 Demand sensor TUONO V4 R Electrical system ELE SYS 107 ...
Page 217: ...INDEX OF TOPICS ENGINE FROM VEHICLE ENG VE ...
Page 237: ...INDEX OF TOPICS ENGINE ENG ...
Page 341: ... Turn the engine with the heads facing upward Tighten the screw 24 TUONO V4 R Engine ENG 341 ...
Page 351: ...INDEX OF TOPICS POWER SUPPLY P SUPP ...
Page 361: ...INDEX OF TOPICS SUSPENSIONS SUSP ...
Page 397: ...INDEX OF TOPICS CHASSIS CHAS ...
Page 419: ...INDEX OF TOPICS BRAKING SYSTEM BRAK SYS ...
Page 431: ...INDEX OF TOPICS COOLING SYSTEM COOL SYS ...
Page 442: ...INDEX OF TOPICS BODYWORK BODYW ...