SERVICE AND SETTING UP
2
- 8
RSV mille
2.3.4 SETTING THE RED LINE THRESHOLD (WITH
ENGINE OFF ONLY)
When the maximum rpm set is exceeded, the red line
warning light LED “
max
” (2) positioned on the dash-
board starts blinking.
If the push button
C
is pressed for less than one second,
the pointer of the revolution counter (1) shifts to the red
line value set for three seconds, after which it returns to
its initial position.
For the setting:
◆
Press the push button
C
, release it and press it again
C
within three seconds.
The pointer (1) moves increasing the value by 1000
rpm at each click, as long as
C
is kept pressed; when it
has reached the maximum value, it starts again from
the beginning.
◆
Press the push button
C
until the desired rpm value
has been set.
◆
If the push button
C
is released and then pressed
again within three seconds, intermittently, the pointer
(1) moves increasing the value by 100 rpm at each
click; when it has reached the maximum value, it starts
again from the beginning.
NOTE
It is not possible to set the red line at values low-
er than 2000 rpm or higher than 12000 rpm.
a
CAUTION
Never exceed the recommended rpm, see table.
◆
To confirm, release the push button
C
.
After three seconds, the red line threshold setting is
stored.
NOTE
The setting is confirmed by the coming on of the
red line warning light LED “
max
” (2).
2.3.5 MULTIFUNCTION (RIGHT DISPLAY)
The right display (multifunction) includes the coolant tem-
perature in °C (°F) and the digital clock as standard set-
tings.
NOTE
When the engine is cold, the writing “
×
”
blinks.
By pressing the push button
D
, the following functions
can be obtained in sequence:
Standard setting:
temperature in °C and digital clock
D
Battery voltage (V BATT)
D
Hour setting
D
Minute setting
D
°C or °F setting
2
x 1000
rpm
aprilia
BORLETTI
VEGLIA
N
max
3
4
5
6
7
8
9 10 11 12
1
1
12
x 1000
rpm
BORLETTI
VEGLIA
N
max
1
2
3
4
5
6
7
8
9 10 11
A
1
2
1
2
3
4
5
6
7
8
9 10 11 12
x 1000
rpm
aprilia
BORLETTI
VEGLIA
N
max
1
Engine maximum rpm
recommended
Mileage km (mi)
rpm
0–1000 (0–625)
6000
1000–1500 (625–937)
7500
oltre 1500 (937)
10500
Summary of Contents for 8140172
Page 1: ...RSV mille MIN 956X Service and repair manual aprilia part 8140172 ...
Page 5: ...0 4 RSV mille NOTE ...
Page 6: ...1 1 RSV mille GENERAL INFORMATION 1 ...
Page 28: ...2 1 RSV mille 1 SERVICE AND SETTING UP 2 ...
Page 84: ...3 1 RSV mille 1 3 ENGINE 3 ...
Page 200: ...4 1 RSV mille 1 2 3 FUEL SUPPLY SYSTEM 4 ...
Page 226: ...5 1 RSV mille 1 2 3 4 COOLING SYSTEM 5 ...
Page 236: ...6 1 RSV mille 6 6 6 6 6 ELECTRICAL SYSTEM 6 ...
Page 239: ...6 4 ELECTRICAL SYSTEM RSV mille 42 0 43 9 54 ...