ELECTRICAL SYSTEM
6
- 13
RSV mille
6.4.9 CHECKING
THE AIR THERMISTOR OPERATION
◆
Remove the left-hand conveyor cover, see 7.1.29 (RE-
MOVING THE AIR CONVEYOR).
◆
Disconnect the two-way connector (1) (coloured
green).
a
CAUTION
When reassembling, make sure the electric connec-
tor (1) is plugged in properly.
◆
Remove the thermistor (2).
◆
Connect a tester (3) (set as an ohmmeter) to the ther-
mistor (2) as illustrated in the figure.
◆
Immerse the thermistor in a container (4) holding water.
◆
Immerse a thermometer (5) with a 0 to 150 °C (32 to
302 °F) range in the same container.
◆
Place the container on a burner (6) and slowly warm up
the liquid.
◆
Check the temperature indicated on the thermometer
(5) and the thermistor value indicated by the tester.
Make sure that the value varies according to the temper-
ature, as indicated.
If values do not vary, or if they depart excessively
from those indicated in the table, change the thermis-
tor (2).
Water temperature
Standard values
(
Ω
) (± 10%)
(°C)
(°F)
20
68
1960 - 2940
40
104
800 - 1200
60
140
400 - 700
80
176
200 - 400
100
212
120 - 250
Summary of Contents for 8140172
Page 1: ...RSV mille MIN 956X Service and repair manual aprilia part 8140172 ...
Page 5: ...0 4 RSV mille NOTE ...
Page 6: ...1 1 RSV mille GENERAL INFORMATION 1 ...
Page 28: ...2 1 RSV mille 1 SERVICE AND SETTING UP 2 ...
Page 84: ...3 1 RSV mille 1 3 ENGINE 3 ...
Page 200: ...4 1 RSV mille 1 2 3 FUEL SUPPLY SYSTEM 4 ...
Page 226: ...5 1 RSV mille 1 2 3 4 COOLING SYSTEM 5 ...
Page 236: ...6 1 RSV mille 6 6 6 6 6 ELECTRICAL SYSTEM 6 ...
Page 239: ...6 4 ELECTRICAL SYSTEM RSV mille 42 0 43 9 54 ...