CSP-CSPS-8000/B Section 1 Page 24 of 30
INDICATORS
EOC (End Of Charge) indicator
LED illuminated when the storage capacitors have reached their potential voltage (~2.5
to 4 kV). In this way the operator can see if the unit is being run faster than the charger
can cope with. If the operator notices loss of data on the recording system, it may mean
the CSP-D is being fired too quickly, not allowing the capacitors to charge to their full
potential. Slowing the repetition rate down until the EOC LED flashes will ensure the
appropriate voltage is reached across the storage capacitors, also the correct energy is
being discharged in the sound source.
FAULT indicator
This indicator will normally illuminate when the unit is powered up, and will extinguish
when the RESET button is pressed. It will otherwise illuminate during most faults.
Please note that the fault light will not illuminate if the thermal cut-out operates in the
charger module.
INTERLOCK indicator
Illuminated if front panel connector is left out when the unit is switched ON or if the lid of
the HV junction box has not been closed correctly. The interlock LED will also illuminate
if the top cover is removed. You will need to press RESET once the interlock condition
has been cured.
TIME OUT indicator
For safety, the HV is switched OFF after a period of approximately 25 - 30 seconds
without key. This also helps preserve the capacitors, as all pulse discharge capacitors
are not designed to sit powered up indefinitely.
HV FAULT indicator
Indicates an output overvoltage, (possibly due to an open circuit capacitor), temperature
fault or low input voltage condition.