![APPLIED ACOUSTICS CSP-S 4000 Manual Download Page 20](http://html.mh-extra.com/html/applied-acoustics/csp-s-4000/csp-s-4000_manual_2955073020.webp)
CSP-CSPS-8000/B Section 1 Page 20 of 30
OPERATION
Once switched on, the ‘HV OFF / RESET’ button must be pressed to reset any fault
latches and the light behind the ‘Manual Key’ button is flashing in sequence with the key
input signal. The output power can now be selected by using the two rotary switches as
shown in the accompanying photographs. The two switches select a combination of
capacitor settings (labelled 1
– 12) and voltage settings (labelled LO, MED and HI) so
the operator can choose the power setting required for the job in hand. Please see next
section. Once the appropriate setti
ng has been made, the ‘HV ON’ button can be
pressed whilst simultaneously turning the ‘HV Enable’ keyswitch clockwise.
A series of up to 5 clicks will be heard depending on the energy selected as the relays
switch in circuit. Once these relays have engaged, the high voltage is enabled.
If the 1-9 power level switch is moved or if the HV off/reset button is pressed, the unit will
shut down safely. In an emergency, the red ‘STOP’ button can be pressed.
The maximum repetition rate is governed by
the charge rate (2800 Joules per second) and
the amount of capacitance selected. For
example, at 300J / shot the CSP-S models
will run at 5 PPS. At 6000J the CSP-S 6000
will operate at 0.33 pulse per second, with a
little in reserve.
Energy Settings.
CSP-S 6000
OUTPUT POWER (JOULES)
SWITCH POSITION
LO
MED
HI
1
200
300
350
2
800
1200
1400
3
1000
1500
1700
4
1200
1800
2100
5
1500
2100
2400
6
2100
3000
3500
7
2300
3300
3900
8
3400
4800
5600
9
3600
5100
6000
Items marked in red are suitable for a single boomer.
All other levels are only suitable for sparker applications.
Summary of Contents for CSP-S 4000
Page 2: ...CSP CSPS 8000 B Section 1 Page 2 of 30 ...
Page 3: ...CSP CSPS 8000 B Section 1 Page 3 of 30 OPERATION MANUAL Section 1 ...
Page 4: ...CSP CSPS 8000 B Section 1 Page 4 of 30 ...
Page 6: ...CSP CSPS 8000 B Section 1 Page 6 of 30 ...
Page 8: ...CSP CSPS 8000 B Section 1 Page 8 of 30 ...