7. Spares
The following spares are available from stock: -
Beacon Connection Cable
RS232 serial cable
30VDC Power supply unit (100-250VAC mains input)
Mains lead (IEC)
1000 Series PRV Actuator
8. Fault Finding
The Smart Switch doesn’t work, what can we do?
Most instances of failure are due to mechanical damage or user error but the possibility of
component failure is always there.
Did the Smart Switch ever work?
If the answer is yes, either the battery is not charged or the Smart Switch is faulty. Look for
mechanical damage and also check if the connectors are damaged.
Try resetting the Smart Switch by depressing the reset button.
If there are no signs of mechanical damage, try charging the Smart Switch.
Check the 30VDC power supply unit is operational.
Check the Beacon Connection Cable for damage. Damage could affect all Smart Switch
functionality with a connected compatible AAE beacon.
If cannot establish communication with a connected 1000 series beacon, turn beacon off and leave
for minimum of 1 minute, then turn beacon back on and retry communication.
If these tests do not help or resolve the problem, contact Applied Acoustic Engineering immediately
for technical assistance.
WARNING: -
If there are any signs of mechanical damage, return the Smart Switch to Applied Acoustic
Engineering for repair.