1082 Smart Switch Operation Manual
CHA-1082-8000/11
__________________________________________________________________________________________________________
__________________________________________________________________________________________________________
Page
35
of
48
to exit
Vent beacon PRV
Standing by
Fast Charge
Charging. . .
Elapsed 1h23m
Timeout!
Halted 7h00m
Smart Switch Terminates Charging After Timeout
Fig. 31
The Smart Switch terminated beacon charging. The Smart Switch monitors overall beacon
charging time. If the overall charging time exceeds a defined time limit or “timeout”, the Smart
Switch terminates beacon charging. This ultimate safety feature is independent of the beacon
chargers own timeout.
NOTE:
-
Timeout is defined automatically from a connected beacon model.
User Terminates Fast Charging Before Completion
Fig. 32
Fast charging can be terminated by the user. Press to terminate fast charging.
NOTE:
-
Fig. 32 elapsed time for example only.
3.8.4 Post Fast Charge Termination
The Smart Switch will now instruct the user to vent the beacon pressure relief valve.
Fig. 33
Press to return to top tier main menu option “Fast Charge”.
NOTE:
-
Fig. 31 halted time for example only.
Refer 3.8.4
Refer 3.8.4