User Manual: Multispot-GI-HT3012
V3.00 (08-2013)
8
■
Getting started: making AC supply connections
Risk of fire / Safety risk
The Multispot-GI-HT3012 requires an AC power source with sufficient
power carriage and correct grounding to ensure safe operation. The AC
power source must be equipped with a circuit breaker and earth
leakage detector. Make sure to only use compliant AC supply lines.
■
Getting started: making DMX control connections
Connect the Multispot-GI-HT3012 to a suitable DMX controller where needed, and
interconnect several units by means of their DMX In/Outputs as required. The last unit
shall be equipped with a proper 120 Ohm termination resistor equipped DMX-plug as
shown in below drawing. Please make sure that all used DMX cables comply to below
standard:
User Manual: Multispot-GI-HT3012
V3.00 (08-2013)
9
■
Operation
All user controls are located on the rear, bottom and side of the backpanel of the unit:
User interface overview:
1
In A-Mode: Speed Control (except A1 = Mix Control)
In C-Mode: Level-Control
2
Display showing the Mode, DMX-address, LOC-function etc.
3
Indicates presence of a DMX signal
4
Indicates the sound-activated mode (internal microphone)
5
MODE selection button
6 UP-button
7 DOWN-button
8
Internal microphone
9
Switches on the termination for the last unit in the DMX-chain
10 Switching the display on or off (with delay)
11 Maintenance (not in use)
12 Power-Input 90-250V AC
13 DMX-Output connector
14 DMX-Input connector
Summary of Contents for multispot HT3012
Page 1: ...Exclusive USA Distributor MultiSpot HT3012...
Page 19: ......