background image

User Manual: Multispot-GI-HT3012                       

                  

 

V3.00 (08-2013)                                                                                                                                                

2

 

 Introduction

 

 

Dear customer, 

 

congratulations on the purchase of a Multiform-branded item and the trust having been 

put in us with this decision. Multiform is one of the leading global manufacturers of 

professional lighting equipment and has decades of experience in design, production 

and quality assurance. 

 

To meet your requirements, this unit has been designed and built to the highest 

standards, so that we can assure you that you have made a good and satisfying 

investment. To take full advantage of all possibilities and for your own safety and the 

safety of your environment, please read these operating instructions carefully before 

you start using the unit.  

 

 Description

 

 

The MultiSpot-GI-HT3012 is a  powerful yet compact RGB color-mixing light fixture for 

indoor applications, which range from architectural purposes to stage lighting. With its 

compact design, high-efficiency drive electronics and advanced cooling system, this 

fixture has been designed for both flexibility and reliability.  

 

SAFETY INFORMATION 

 

 

Read the safety precautions in this chapter before installing, 

powering up, operating or servicing this device. Failure to do so 

may void the product warranty, and releases the manufacturer 

from all product liability.  

 

■ 

Symbols used in this manual 

 

The following symbols are used to identify important safety information on the product 

and in this manual: 

 

 

WARNING!

 Read manual before installation, operation or servicing.  

 

WARNING! 

Safety hazard. Risk of injury or death.

 

 

WARNING! 

Hazardous voltage. Risk of severe or fatal electric shock.

 

User Manual: Multispot-GI-HT3012                       

                  

 

V3.00 (08-2013)                                                                                                                                                

15

 

every 2 seconds). Pressing the MODE button again for more than 3 seconds unlocks 

the button- and potentiometer-functions. Please note: If the display is in OFF-mode it 

will take approximately 25 seconds before the display switches off. It will be switched 

on again if any key is touched and will switch off again after 25 seconds if the keys are 

not unlocked by the procedure mentioned above.  

 

Termination 

 

To avoid interference the last unit of a DMX-chain should be terminated. Therefore the 

DIP switch (9) of the last unit in the DMX-chain must be switched ON.  

 

Switch on condition 

The unit always returns to the last mode before it was switched off; in DMX modes 

however  DMX values are cleared if power is switched off. 

 

DMX signal drop condition 

 

The device will retain the status that it was in before the DMX signal got lost, but 

potential tact settings will be automatically cleared.  

 

■ 

Maintenance

 

 

This unit does not need regular maintenance. The internal circuit is protected by a 

250V/2A slow-blow fuse 5x20mm fuse. If this fuse fails, this usually indicates an 

internal fault requiring servicing by a qualified engineer.  

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Summary of Contents for multispot HT3012

Page 1: ...Exclusive USA Distributor MultiSpot HT3012...

Page 2: ...ior quality and value Focused on you our goal is to ensure unparalleled support from the initial conversation to after sales service Our lighting experts and engineers will consult with you on ways to...

Page 3: ...ER MANUAL MULTISPOT GI HT3012 High Power RGB LED Lighting Fixture For firmware 50 010 0018 00111 1 00 RevL ENGLISH Page 2 15 Updated versions of this document may be available at WWW MULTIFORM LIGHTIN...

Page 4: ...ot GI HT3012 is a powerful yet compact RGB color mixing light fixture for indoor applications which range from architectural purposes to stage lighting With its compact design high efficiency drive el...

Page 5: ...are Punches big forces and heavy vibration may damage this product mechanically Protection from eye injury 1 Warning Depending on the configuration of the device this device may reach or exceed the li...

Page 6: ...m 6 ins between this unit and other devices or a wall to allow for proper cooling 3 Take always care of sufficient air convection in the unit s environment to avoid overheating Make sure air convectio...

Page 7: ...onsequently take care of your dealer or maintenance company to be authorized by the manufacturer Health advice This unit produces and absorbs electromagnetic radiation The strength of radiation and th...

Page 8: ...ntains the following items and contact your dealer immediately for replacement if any part is missing Main parts 1 pc Multispot GI HT3012 passive RGB LED panel 1 pc PS020A 2 DMX controlled 3 channel p...

Page 9: ...stalled out of reach of people and outside areas where persons may walk by or be seated Make sure that the installation area can hold a minimum point load of 10 times the device s weight In fixed inst...

Page 10: ...ircuit breaker and earth leakage detector Make sure to only use compliant AC supply lines Getting started making DMX control connections Connect the Multispot GI HT3012 to a suitable DMX controller wh...

Page 11: ...e Level Control 2 Display showing the Mode DMX address LOC function etc 3 Indicates presence of a DMX signal 4 Indicates the sound activated mode internal microphone 5 MODE selection button 6 UP butto...

Page 12: ...rks from a built in microphone 8 which picks up the environmental sound Its activity is shown by the flashing of the right dot 4 in the display The level for all patterns is maximum In A mode the unit...

Page 13: ...ws C indicating operation in C mode Then choose by using the UP DOWN buttons 6 7 one of the 19 presets as shown in the list below Changing the setting becomes effective directly Knob 1 determines the...

Page 14: ...master slave operation the slave units shall be set to d3 mode d4 Mode DMX 4 Channel Combined Master Strobe Mode Press the MODE button 5 until the display shows d4 indicating operation in d4 4 Channel...

Page 15: ...intensity CH4 000 255 Master dimmer CH5 000 255 000 049 Strobe off 050 255 Strobe rate 050 slow 255 max speed 23 Hz This setting is stored even if the device is switched off P DMX Preset Mode If you w...

Page 16: ...H3 050 255 Chase speed CH4 000 049 Tact off 050 255 Tact 050 slow 255 max speed 23 Hz The pre programmed soft fade or hard switching patterns can be chosen by means of CH1 whilst CH2 is used as a leve...

Page 17: ...erference the last unit of a DMX chain should be terminated Therefore the DIP switch 9 of the last unit in the DMX chain must be switched ON Switch on condition The unit always returns to the last mod...

Page 18: ...Type Pulse Density Modulation PDM Dimensions with straight bracket WxHxD 269 0 x 275 7 x 115 0mm Weight 2 8kg Standards This product complies with the following standards EU electrical safety EN60598...

Page 19: ......

Page 20: ...Apollo Design Technology Inc 260 497 9191 ApolloDesign net Copyright 2016 Apollo Design Technology Inc 4 16 MultiSpot HT3012...

Reviews: