background image

19

andassemble the nuts M20 on it.
Adjust each rack in equal height by tightening or unloosing
the nuts.
Adjust  each  cable  in  equal  tension  by  tightening  or
unloosing the nuts.
                                                                    Fig.13

7.8ANCHORING COLUMNS 

Before proceeding, check the measurement referring to the layout figure 2 and make sure that the base 
plate of each column is square. 

Using the base plate as guide, drill each hole in the concrete approximately100mm deep with the 
rotary hammer drill D.17. To assure full holding power, do not ream the hole or allow drill to wobble. 
After drilling, remove dust thoroughly from each hole using compressed air or wire brush. 
Assemble the washers and nuts on the anchors then tap into each hole with a hammer until the washer
rests against the base plate. Be sure if shimming is required, enough threads are left exposed. 
If shimming is required, insert the shims as necessary around the anchor bolts, the columns will be
plumb. 
With the shims and anchor bolts in place, tighten by securing the nut to the base.

7.9

HYDRAULIC SYSTEM CONNECTION 

When routing the hydraulic hose, make sure that the hose is clear ofmoving
part, make sure to keep the hose and fittings clean from dust. Failure to do so 
may result in hydraulic line failure which may result in damage or personal 
harm.

Fix the hydraulic power unit onto the support mounted on the power-side column using the supplied 
screws M8X35, washers D.8 and locking washers D.8 .
Route the hydraulic hoses .
Tighten the fittings thoroughly

7.10 MAKE THE ELECTRICAL HOOKUP TO THE POWER UNIT

The hookup work must be carriedout by a qualified electrician.
Make sure that the power supply is right.
Make sure the connection of the phases is right.
The power unit must be kept dry.

Install the control panel onto the power-side column using the supplied screws 
Make the electric hookup to the hydraulic power unit referring to the wiring diagram (fig. 6) using 
included electric cable.
Make sure te connection of the phases is right and the lift is grounded

7.11

OIL FILLING AND BLEEDING 

DO NOT run power unit with no oil. Damage to pump can occur.
If motor gets hot or sounds peculiar, stop immediately and recheck the electric 
connection.

Use the hydraulic fluid recommended in the chapter 5.3. 

Summary of Contents for HW-12S

Page 1: ...Four post vehicle lift Original Operation Manual...

Page 2: ...eed proper care Indicates prohibition Indicates a possibility of danger for the operators BOLD TYPE Indicates the direction of access for motor vehicles to the lift Important information WARNING befor...

Page 3: ...INFORMATION 4 2 PRODUCT IDENTIFICATION 6 3 PACKING TRANSPORT AND STORAGE 7 4 PRODUCT DESCRIPTION 8 5 TECHNICAL SPECIFICATION 9 6 SAFETY 12 7 INSTALLATION 15 8 OPERATION AND USE 22 9 MAINTENANCE 26 10...

Page 4: ...s overhauling and dismantling of the lift THE MANUFACTURER IS NOT RESPONSIBLE FOR POSSIBLE DAMAGE TO PEOPLE VEHICLES OROBJECTS IF SAID OPERATIONS ARE CARRIED OUT BY UNAUTHORIZED PERSONNEL OR THE LIFT...

Page 5: ...ause damage to people or objects DECLARATION OF WARRANTY AND LIMITATION OF LIABILITY The manufacturer has paid proper attention to the preparation of this manual However nothing contained herein modif...

Page 6: ...authorized modifications to the machine or parts of it are carried out The presence of defects in workmanship must be verified by the Manufacturer s personnel in charge 2 2 TECHNICAL SERVICING For all...

Page 7: ...ragile parts 3 3 STORAGE AND STACKING OF PACKAGES Packages must be stored in a covered place out of direct sunlight and in low humidity at a temperature between 5 C and 40 C Stacking is not recommende...

Page 8: ...ed of four columns N 1 power side column 1 N 3 off side columns 2 two platforms the power side platform 3 and the off side platform 4 and two transverse beams 6 and one jacking beam 5 anchored to the...

Page 9: ...nway length 5000mm Runway width 580mm Free width between runways 880 960mm Width between two columns 2880mm Overall length 5825mm Overall height 2220mm Overall width 3286mm Raised time 60s Noise level...

Page 10: ...h Figure 4 HYDRAULIC POWER UNIT Figure 5 HYDRAULIC PLAN A1 Motor A6 Lowering speed control valve A2 Oil filter A7 Non return valve A3 Oil tank A8 Manual lowering valve A4 Pressure overload valve A9 Di...

Page 11: ...11...

Page 12: ...FU2 Thermal relay SQ Top limit switch FU3 Thermal relay KM Contactor AC TC Transformer HL Polit lamp Figure 6b ELECTRICAL PLAN 220V QF Power switch SB1 scram button FU1 Thermal relay SB2 Lifting push...

Page 13: ...e during working is only admitted when the vehicle is lifted and runways are not running Never use the lift when safety devices are off line People the lift and the vehicles lifted can be seriously da...

Page 14: ...SK OF THE VEHICLE FALLING FROM THE LIFT Vehicle falling from the lift can be caused when the vehicle is improperly placed on platforms and when its dimensions are incompatible with the lift or by exce...

Page 15: ...ctly forbidden during lifting as well as when the vehicle has been already lifted Fig 11 6 10 RISKS DURING VEHICLE LIFTING AND WORKING To avoid overloading and possible breaking during lifting and wor...

Page 16: ...ust not be next to washing areas painting workbenches solvent or varnish deposits The installation near to rooms where a dangerous situation of explosion can occur is strictly forbidden The relevant s...

Page 17: ...Elevate runways off the floor with blocks of wooed to prevent any damage Pay attention that T fitting for air supply is closest to the power side of the lift Unpack the lift by removing all wrapping f...

Page 18: ...each column toward the respective end of the transverse beam until stopped by the slide block on the transverse beam Make sure that all columns are positioned in the correct location ref fig 2 Make su...

Page 19: ...RAULIC SYSTEM CONNECTION When routing the hydraulic hose make sure that the hose is clear ofmoving part make sure to keep the hose and fittings clean from dust Failure to do so may result in hydraulic...

Page 20: ...ding Make sure to check all plastic sliders are on the position and greased properly Make sure to check all pins are installed correctly and greased properly Make sure to check all bolts nuts and scre...

Page 21: ...on the power side column as shown in the figure 14 Fig 14 7 14 INSTALLATION OF ACCESSORIES ref fig 15 Install all covers onto transverse beams Install the front wheel stops Install the drive on ramps...

Page 22: ...e lift Carried out two or three complete cycles of lowering with the vehicle loaded and lifting and Repeat the checks provided for by 7 13 Check no strange noise during lifting and lowering If the run...

Page 23: ...ck for the safety operation by lowering the jack CHAPTER 8 OPERATION AND USE Never operate the lift with any person or equipment below Never exceed the rated lifting capacity Always ensure that the me...

Page 24: ...seof the lift 0 1 position the electric circuit is powered PLIOT LAMP 2 It shows that the electric circuit is Powered LIFTING BUTTON 3 0 When pressed the power unit is running and the lift can be rais...

Page 25: ...el while being lowered Lower the lift fully by keeping pressing both the safety release handle and the lowering handle Remove the wheel chops and check to be sure that the area is clear before removin...

Page 26: ...jacking beam with any person Never exceed the rated lifting capacity Always ensure that the mechanical safeties are engaged before any attempt is made to work on or near the vehicle 8 2 1 LIFTING Chec...

Page 27: ...quired Follow the scheduled maintenance and check periods shown in the manual Discover the reason for possible failures such as too much noise overheating oil blow by etc Refer to documents supplied b...

Page 28: ...sary Check hydraulic systems for proper operation Every 12 months Verify that all components and mechanisms are not damaged Verify the steel cables are not worn up to 5 change if necessary Check the e...

Page 29: ...The pump is faulty Check the pump and replace if needed Oil leakages in hydraulic circuit Check the circuit for any leakage The lift does not move smoothly Lubrication of sliders is not enough Grease...

Page 30: ......