19
andassemble the nuts M20 on it.
Adjust each rack in equal height by tightening or unloosing
the nuts.
Adjust each cable in equal tension by tightening or
unloosing the nuts.
Fig.13
7.8ANCHORING COLUMNS
Before proceeding, check the measurement referring to the layout figure 2 and make sure that the base
plate of each column is square.
Using the base plate as guide, drill each hole in the concrete approximately100mm deep with the
rotary hammer drill D.17. To assure full holding power, do not ream the hole or allow drill to wobble.
After drilling, remove dust thoroughly from each hole using compressed air or wire brush.
Assemble the washers and nuts on the anchors then tap into each hole with a hammer until the washer
rests against the base plate. Be sure if shimming is required, enough threads are left exposed.
If shimming is required, insert the shims as necessary around the anchor bolts, the columns will be
plumb.
With the shims and anchor bolts in place, tighten by securing the nut to the base.
7.9
HYDRAULIC SYSTEM CONNECTION
When routing the hydraulic hose, make sure that the hose is clear ofmoving
part, make sure to keep the hose and fittings clean from dust. Failure to do so
may result in hydraulic line failure which may result in damage or personal
harm.
Fix the hydraulic power unit onto the support mounted on the power-side column using the supplied
screws M8X35, washers D.8 and locking washers D.8 .
Route the hydraulic hoses .
Tighten the fittings thoroughly
7.10 MAKE THE ELECTRICAL HOOKUP TO THE POWER UNIT
The hookup work must be carriedout by a qualified electrician.
Make sure that the power supply is right.
Make sure the connection of the phases is right.
The power unit must be kept dry.
Install the control panel onto the power-side column using the supplied screws
Make the electric hookup to the hydraulic power unit referring to the wiring diagram (fig. 6) using
included electric cable.
Make sure te connection of the phases is right and the lift is grounded
7.11
OIL FILLING AND BLEEDING
DO NOT run power unit with no oil. Damage to pump can occur.
If motor gets hot or sounds peculiar, stop immediately and recheck the electric
connection.
Use the hydraulic fluid recommended in the chapter 5.3.