![Apex Digital STX104 Reference Manual Download Page 99](http://html.mh-extra.com/html/apex-digital/stx104/stx104_reference-manual_2952893099.webp)
TSS[3:0]
rw
0000
Start Trigger Synchronization Source.
0000 = none (default)
0001 = writing 0x5A to the software strobe register
0010 = none
0011 = Analog Input Sample/Frame ( see page 15) Timer
0010 = none
0011 = none
0100 = 8254 Counter 0 Output (CT_OUT0) rising-edge
0101 = 8254 Counter 0 Output (CT_OUT0) falling-edge
0110 = 8254 Counter 2 Output (CT_OUT2) rising-edge
0111 = 8254 Counter 2 Output (CT_OUT2) falling-edge
1000 = DIN0 rising edge
1001 = DIN0 falling edge
1010 = DIN1 rising edge
1011 = DIN1 falling edge
1100 = DIN2 rising edge
1101 = DIN2 falling edge
1110 = DIN3 rising edge
1111 = DIN3 falling edge
ETS[3:0]
rw
0000
End/Stop Trigger Source
0000 = none (default)
0001 = writing 0xAA to the software strobe register
0010 = Analog Input Frame ( see page 15) Maximum
0011 = Analog Input Sample/Frame ( see page 15) Timer
0100 = 8254 Counter 0 Output (CT_OUT0) rising-edge
0101 = 8254 Counter 0 Output (CT_OUT0) falling-edge
0110 = 8254 Counter 2 Output (CT_OUT2) rising-edge
0111 = 8254 Counter 2 Output (CT_OUT2) falling-edge
1000 = DIN0 rising edge
1001 = DIN0 falling edge
1010 = DIN1 rising edge
1011 = DIN1 falling edge
1100 = DIN2 rising edge
1101 = DIN2 falling edge
1110 = DIN3 rising edge
1111 = DIN3 falling edge
11.40 Trigger Configuration (Index=16,