AQUAKOND AKY
CONDENSING BOILER
22
code HC0048.10GB ed.B-1811
AKY
SB Lockout indicator light
RS Reset button
I/O ON-OFF switch
TA Room thermostat [to be fitted
by the installer]
GREY
BROWN
PINK
TA
C09660
I/0
RS
SB
[24Vdc]
HC0047 C2 009
1
R2
0
F9
R5
6
C26
Q1
R8
C
N1
5
R
10
4
R22
R8
7
C
49
F5
D6
C50
C32
R39
U15
C41
Q2
CN
11
R4
8
U1
C
N1
2
C28
R
61
R24
U8
C
21
F3
R3
R50
R27
F4
U2
R1
6
R1
U4
R29
CN04
C42
R4
4
R
66
F6
R
52
TP1
R83
R4
R
73
R101
C54
C55
C18
R1
7
U9
R
65
R2
R91
C35
R
97
C6
O
P1
L1
DZ1
C1
T2
D11
D16
C12
R90
C34
R
103
F1
D7
R3
7
R7
R1
8
R7
4
CN13
D17
R5
C37
R99
C31
C2
SW
1
R94
C
52
R34
U3
F8
C56
R89
C
14
R
25
F2
R
10
6
R77
R43
C
27
R49
R1
0
R5
8
C40
C
20
C8
Q5
R4
5
R
62
RL2
C
22
R6
4
D3
C
23
CN01
LC
1
R32
RL1
C51
U
11
LC6
C11
R70
R41
R40
D9
D1
R35
R
11
0
R4
2
R31
R59
R96
TS1
R38
D5
D
20
Q3
R23
D
2
R
55
R2
6
CN02
D10
C29
R
100
C15
C33
D13
R1
9
R78
R108
R10
2
R76
R79
D8
C
43
TS2
C5
C1
0
R9
U1
4
LC5
LC2
C38
C
17
Q6
VR
1
CN08
C3
R
71
R95
R
72
R1
2
T1
C36
C53
R
10
7
U5
D4
R82
XT1
C
48
F7
R8
8
C30
R2
8
R1
4
C39
R63
R54
R1
1
U1
3
R
53
C46
RR1
C16
C45
R
10
9
R1
3
C
44
CN06
LC3
J1
U1
0
R30
R
57
R1
5
R21
R36
C
N1
4
R
98
R86
R
60
C9
D14
D19
D
12
R6
9
CN07
R84
C7
D15
D21
R93
RD1
C47
R
10
5
R8
1
LC4
R4
7
R6
7
R92
R51
R6
8
Q4
R85
R75
CN
05
C
25
U
12
CN03
C
13
R6
R8
0
R33
C4
D1
8
LF
N
+5V
B3
G
ND
+5V
B2
G
N
D
B1
G
N
D
NTC3
NTC3
N
NTC2
NTC2
NTC1
NTC1
D-
D+
GND
+12V
+28V
HAL
L
L1
PWM
G
ND
ID2
IDC
2
ID3
IDC
4
ID4
IDC
5
ID5
IDC
6
N
ID6
+28V
Y2
Y1
G
ND
Q
2
C
O
M
N.
C.
N.
O
.
N
N
L
GND
7Vdc
24Vac
24Vdc
CLK
DAT
NC
IDC1
ID1
LBW
Power supply plug
YELLOW
GREEN
5.5. Electrical Connections
5.5.1. Boiler power supply
The boiler must be correctly connected to an effective earthing
system, fitted in compliance with current legislation.
Single phase 230Vac power supply with neutral; do not swap
the neutral with the live wire. For safety reasons, if the live and
neutral wires are swapped, the flame control prevents operation
reaching F10.
The boiler can be connected to the mains power supply with
a plug-socket only if the latter does not allow live and neutral
to be swapped.
The electrical system, and more specifically the cable section,
must be suitable for the equipment maximum power consumption
(see technical features table).
Keep electric cables away from heat sources.
N
ote: It is compulsory to fit, upstream of the boiler,
a multipole isolator fitted with a suitable electric
protection element.
Cable section
: live, neutral and earth cable section 1.0 mm²
5.5.2. Connecting the ambient thermostat and the C09660 remote control
The boiler must be compulsorily
connected to an ambient thermostat;
the C09660 remote control should
at least be connected to allow the
customer to remotely reset.
Connect the ambient thermostat
to the ID2/IDC2 terminals of the
boiler PCB. If used with the C09660
remote control, follow the diagram
shown to the side.
The thermostat, switch and lamp
contacts are supplied by low
voltage.
The thermostat contact must have
zero voltage.
Should the installer decide to fit a
lockout warning light, its power supply
must be 24VDC and its maximum
power input must be < 25 mA.
Cable section
: contact and light
0.5 mm