Trouble shooting

NO.

1

2

The mainboard is abnormal-the orange light is off

Return to factory for maintenance

3

4

Confirm the installation location and stay away from surrounding conductors, 

confirm whether the electrode needle is close to or touching the metal conductor and 

remove foreign objects

Return to factory for maintenance
Return to factory for maintenance

5

Return to factory for maintenance

Return to factory for maintenance

Check the grounding of the ion bar and plant equipment, and return to the factory 

for maintenance

6

Return to factory for maintenance

Safety warning

1.

Please read the instruction manual carefully before installing and using this equipment.

2.

The whole set of equipment must be reliably grounded during use, otherwise it is easy to cause abnormality or even damage to the ion bar.

3.

Do not use this equipment in environment where humidity is > 70%.

4.

It is strictly forbidden to use this equipment in flammable and explosive environments.

5.

Unauthorized disassembly of the product is strictly prohibited, internal maintenance and repair must be performed by professionals.

6.

It is strictly forbidden to touch liquid during use

,

 otherwise an abnormality may occur and cause electric shock or fire.

7.

Power must be turned off during inspecting or replacing the product, otherwise it may cause electric shock or fire.

8.

The product is ventilated with dry and clean air or nitrogen which will work abnormally or be damaged if the gas source contains water or 

grease.

9.

The product is specially designed to eliminate static electricity. It is strictly forbidden to use it for other purposes. Any abnormal use may 

cause machine failure, electric shock, fire and other accidents.

10.

Its strictly forbidden to touch the electrode needles when power is on, otherwise it is easy to cause malfunctions and electric shock 

accidents.

11.

The electrode needle is a sharp metal object, please use it with care.

12.

Please check the specifications of the power supply before powering on the product. Any power supply that does not meet the 

specifications will cause damage to the product.

13.

Please check the product power cord/communication cord regularly and replace it immediately if it is damaged. Otherwise it is easy to 

cause problems such as electric leakage, poor communication, and abnormal operation.

Problems

Reasons

Solutions

The indicator on the label 

panel is off

pa

 

Poor contact of the power cable

Check whether the power cable is in good condition and  securely connected

Power supply mismatch

Confirm the power supply specification

INPUT

100—240VAC 50/60Hz

OUTPUT

24VDC 2000mA

Electromagnetic interference

Abnormal discharge

No power supply for high voltage module

High voltage module is damaged

Panel indicator red light on 

The product is smoky or burnt

High voltage module is damaged or insulation of 

the discharge seat is damaged

Main-board chip is damaged caused by poor 

grounding or no grounding

High voltage module is damaged

Main-board chip is damaged

Unable to discharge

Check whether the power cable is in good condition and  securely connected

Confirm the power supply specification

INPUT

100—240VAC 50/60Hz

OUTPUT

24VDC 2000mA

Turn off the power switch / unplug the power cable, restart the ion

 bar

The electrostatic removal 

performance decreased  

Whether the discharge seat is tightened

Discharge needle is polluted and damaged

Bearing set of ion bar is improper

There are conductors or other 

ion bar 

around 

Confirm the discharge seat is tightened

Clean or replace the discharge needle

Confirm the best bearing set

Remove (moving) conductors or other 

ion bar

No power supply, power-on indicator-green light is off

Check the power supply cable

Poor contact of the power cable

Power supply mismatch

The indicator of the RJ45 

interface is off  

(green light 

indicates power-on, orange 

light flashes with working 

frequency)

Summary of Contents for AP-DB1223

Page 1: ...Distant Space Static Removal Ion Bar Shanghai Anping Static Technology Co Ltd AP DB1223...

Page 2: ...oelectronics semiconductor and other industries Effectively solve the problems caused by static electricity Prevent adhesion of objects Static removal Prevent blockage of feeder Prevent static electri...

Page 3: ...c elimination device developed and produced by Anping Company to eliminate static electricity and maintain static balance in clean spaces which adopts a DC high voltage power supply and a special sili...

Page 4: ...sitive and negative ions cycle setting Note This adjustment function can only be effective if the coding switch is in C or D position Adjust balance IBN Press IBN first then press when the positive vo...

Page 5: ...discharge speed TIME Reduce the negative high voltage amplitude the negative ion output decreases Adjust ion balance voltage TIME TIME TIME Adjust ion balance voltage Increase the negative high voltag...

Page 6: ...nd its static elimination ability can be exerted no matter in short or long distance In addition the discharge frequency can be adjusted which can extend the discharge distance The output ratio of pos...

Page 7: ...city No 2 Working status indicator Green light Normal work Red light Abnormal high voltage Blue light Infrared adjustment pause cleaning indication No 3 Features Safe Easy to use Durable Electroshock...

Page 8: ...ar installed End to end connection in series to simplify wiring The product can be switched on from end to end to simplify wiring Each adapter power supply can load up to 2 space bars Features Safe Ea...

Page 9: ...Status indicator Coding switch Power connector Front Back port Three phase power socket Two middle electrodes spacing is 200mm two end electrodes spacing is 100mm RJ45 power communication port Install...

Page 10: ...djusted by remote control Ozone thickness 0 1ppm 50mm away from the emitter electrode Alarm indicator Green light Normal work Red light Abnormal high voltage Blue light Debugging cleaning indication R...

Page 11: ...function information 1 Orange 24VDC 2 White orange 24VDC 3 Blue RS485 B 4 White blue RS485 A 5 Green GND 6 White green GND 7 Brown HVAL Eliminator high voltage alarm 8 White brown ACT Eliminator power...

Page 12: ...2 6 1LML05000 M5 4 AP6620006 AP2253011 1 Packing accessories OK CTTH PWM FREQ CFM IBV IBN 1 2 3 6 5 4 IBP CAL ALTH AP T R Part name Picture Part No Specification Qty L shaped stainless steel mounting...

Page 13: ...ctric shock accidents 11 The electrode needle is a sharp metal object please use it with care 12 Please check the specifications of the power supply before powering on the product Any power supply tha...

Page 14: ...r body and the panel indicator light are off it should be stopped and repaired by professional maintenance personnel It can be used only after the electrical performance index is normal Maintenance Af...

Page 15: ...g analysis and elimination solution provider Speciality Creates Value AP T Shanghai Anping Static Technology Co Ltd Tel 86 21 64517676 Fax 86 21 64517673 Postcode 200233 Website www ap static com Addr...

Reviews: