background image

Take out ion bar, power adapter, power cable, stainless 

steel  mounting  bracket  and  other  accessories  from  the 

packing  box  and  install  the  stainless  steel  mounting 

bracket on the mounting slot of the ion bar base. Select 

the best static discharge position and install the bar body 

and the supporting power supply firmly.

Insert one end of the power cord into the socket of the 

power adapter, and the other end into the power port on 

the  bar  body.  The  port  wiring  information  is  shown  in 

the table below.

Bracket installation

Adjustable bracket

The network port power indicator light on and the panel 

indicator  light  green  shows  ion  bar  working  normally. 

Adjust  the  appropriate  voltage  output  parameters  to 

output  positive  and  negative  ions  to  neutralize  the 

electrostatic charge in the space.

1

2

3

Step of use

+

-

OK

CT

TH

PWM

FREQ

CFM

IB

V

IB

N

1

2

3

6

5

4

IB

P

CAL

AL

TH

AP&T

R

Network port cable function information

1

Orange

+24VDC

2 White-orange

+24VDC

3

Blue

RS485+B

4 White-blue

RS485+A

5

Green

GND

6 White-green

GND

7

Brown

HV

AL

Eliminator high voltage alarm

8 White-brown ACT

Eliminator  power-on indication 

Clean

Eliminator cleaning indication

9 Metal shield

PE

The output wiring diagrams of pins 7 and 8 are as 

follows:

AP-DB1223 coding switch

0

Pause / modify address 

  1

0.01HZ

  2

0.03HZ

  3: 0.05HZ

  4: 0.07HZ

  5: 0.1HZ

  6: 0.3HZ

  7: 0.5HZ

  8: 0.7HZ

  9: 1HZ

  A: 3HZ

  B: 5HZ

  C: Remote control / terminal control

  D: Remote control / terminal control

E: Negative high voltage output (P:95%

N:5%-105HZ)

F: Positive high voltage output (N:95%

P:5%-105HZ)

Indicator function

Blue light: Infrared adjustment/pause/cleaning indication

Green light: Normal work

Red light: Alarm indication

NPN 

function

7: High voltage indication

8: Power-on indication, cleaning indication

Connect to AC

power supply

cable

cable

Network port adapter

Products Use

Step of use/Installation position/Packing accessories

HV Alarm signal:Normal--always 

open

Abnormal--always close

Power signal :Normal--always close

cleaning signal

:Clean--always open

Summary of Contents for AP-DB1223

Page 1: ...Distant Space Static Removal Ion Bar Shanghai Anping Static Technology Co Ltd AP DB1223...

Page 2: ...oelectronics semiconductor and other industries Effectively solve the problems caused by static electricity Prevent adhesion of objects Static removal Prevent blockage of feeder Prevent static electri...

Page 3: ...c elimination device developed and produced by Anping Company to eliminate static electricity and maintain static balance in clean spaces which adopts a DC high voltage power supply and a special sili...

Page 4: ...sitive and negative ions cycle setting Note This adjustment function can only be effective if the coding switch is in C or D position Adjust balance IBN Press IBN first then press when the positive vo...

Page 5: ...discharge speed TIME Reduce the negative high voltage amplitude the negative ion output decreases Adjust ion balance voltage TIME TIME TIME Adjust ion balance voltage Increase the negative high voltag...

Page 6: ...nd its static elimination ability can be exerted no matter in short or long distance In addition the discharge frequency can be adjusted which can extend the discharge distance The output ratio of pos...

Page 7: ...city No 2 Working status indicator Green light Normal work Red light Abnormal high voltage Blue light Infrared adjustment pause cleaning indication No 3 Features Safe Easy to use Durable Electroshock...

Page 8: ...ar installed End to end connection in series to simplify wiring The product can be switched on from end to end to simplify wiring Each adapter power supply can load up to 2 space bars Features Safe Ea...

Page 9: ...Status indicator Coding switch Power connector Front Back port Three phase power socket Two middle electrodes spacing is 200mm two end electrodes spacing is 100mm RJ45 power communication port Install...

Page 10: ...djusted by remote control Ozone thickness 0 1ppm 50mm away from the emitter electrode Alarm indicator Green light Normal work Red light Abnormal high voltage Blue light Debugging cleaning indication R...

Page 11: ...function information 1 Orange 24VDC 2 White orange 24VDC 3 Blue RS485 B 4 White blue RS485 A 5 Green GND 6 White green GND 7 Brown HVAL Eliminator high voltage alarm 8 White brown ACT Eliminator power...

Page 12: ...2 6 1LML05000 M5 4 AP6620006 AP2253011 1 Packing accessories OK CTTH PWM FREQ CFM IBV IBN 1 2 3 6 5 4 IBP CAL ALTH AP T R Part name Picture Part No Specification Qty L shaped stainless steel mounting...

Page 13: ...ctric shock accidents 11 The electrode needle is a sharp metal object please use it with care 12 Please check the specifications of the power supply before powering on the product Any power supply tha...

Page 14: ...r body and the panel indicator light are off it should be stopped and repaired by professional maintenance personnel It can be used only after the electrical performance index is normal Maintenance Af...

Page 15: ...g analysis and elimination solution provider Speciality Creates Value AP T Shanghai Anping Static Technology Co Ltd Tel 86 21 64517676 Fax 86 21 64517673 Postcode 200233 Website www ap static com Addr...

Reviews: