background image

1) Place the ion bar in the working area where static electricity is to be eliminated and the installation angle is perpendicular to the surface of the

charged body.

2) Ion bar should be at least 10cm away from the metal conductor and metal grounding body around the electrode and the bar body must be reliably

connected to the ground wire.

Installation position

Power adapter

AP2930003

1

National standard 

power cord

8YXG25110

1

8WXI00004

1

8WXI00002

AP8038005

4

M5 Flake Slider Nut

AP8933000

M5*12*12*4

2

AP8943000

M5

6

AP8946004

M5

6

AP8900001

M5*12

6

1LML05000

M5

4

AP6620006

——

——

AP2253011

1

Packing accessories

OK 

-

CT

TH

PWM

FREQ 

CFM

IB

V

IB

N

1

2

3

6

5

4

IB

P

CAL

AL

TH

AP&T

R

Part name

Picture

Part No.

Specification

Qty

L-shaped stainless steel 

mounting bracket

Single-end crystal 

head black shield 

ethernet cable

Double-end crystal 

head black shield 

ethernet cable

Hex nuts

304 stainless steel 

spring washer

304 stainless steel flat 

gasket

304 stainless steel pan 

head Phillips screw

Remote control

Needle holder 

GRT-240200 DC24V 2A P/N:1/2+ 5/6- network 

metal PE

Standard 1.8m

optional 3m/5m

Standard 2.5m

optional 5m/10m

FUTP CAT.5E 26AWG 4Pair Jacket 

PVC OD:5.6±0.2mm  bag packed

Optional

Height  25mm /Width 16mm/ 

Thickness 3mm/Aperture  

5mm

measured 4.8mm

Infrared remote control 

L*W*H 

85.76*39.76*6.66

 

Summary of Contents for AP-DB1223

Page 1: ...Distant Space Static Removal Ion Bar Shanghai Anping Static Technology Co Ltd AP DB1223...

Page 2: ...oelectronics semiconductor and other industries Effectively solve the problems caused by static electricity Prevent adhesion of objects Static removal Prevent blockage of feeder Prevent static electri...

Page 3: ...c elimination device developed and produced by Anping Company to eliminate static electricity and maintain static balance in clean spaces which adopts a DC high voltage power supply and a special sili...

Page 4: ...sitive and negative ions cycle setting Note This adjustment function can only be effective if the coding switch is in C or D position Adjust balance IBN Press IBN first then press when the positive vo...

Page 5: ...discharge speed TIME Reduce the negative high voltage amplitude the negative ion output decreases Adjust ion balance voltage TIME TIME TIME Adjust ion balance voltage Increase the negative high voltag...

Page 6: ...nd its static elimination ability can be exerted no matter in short or long distance In addition the discharge frequency can be adjusted which can extend the discharge distance The output ratio of pos...

Page 7: ...city No 2 Working status indicator Green light Normal work Red light Abnormal high voltage Blue light Infrared adjustment pause cleaning indication No 3 Features Safe Easy to use Durable Electroshock...

Page 8: ...ar installed End to end connection in series to simplify wiring The product can be switched on from end to end to simplify wiring Each adapter power supply can load up to 2 space bars Features Safe Ea...

Page 9: ...Status indicator Coding switch Power connector Front Back port Three phase power socket Two middle electrodes spacing is 200mm two end electrodes spacing is 100mm RJ45 power communication port Install...

Page 10: ...djusted by remote control Ozone thickness 0 1ppm 50mm away from the emitter electrode Alarm indicator Green light Normal work Red light Abnormal high voltage Blue light Debugging cleaning indication R...

Page 11: ...function information 1 Orange 24VDC 2 White orange 24VDC 3 Blue RS485 B 4 White blue RS485 A 5 Green GND 6 White green GND 7 Brown HVAL Eliminator high voltage alarm 8 White brown ACT Eliminator power...

Page 12: ...2 6 1LML05000 M5 4 AP6620006 AP2253011 1 Packing accessories OK CTTH PWM FREQ CFM IBV IBN 1 2 3 6 5 4 IBP CAL ALTH AP T R Part name Picture Part No Specification Qty L shaped stainless steel mounting...

Page 13: ...ctric shock accidents 11 The electrode needle is a sharp metal object please use it with care 12 Please check the specifications of the power supply before powering on the product Any power supply tha...

Page 14: ...r body and the panel indicator light are off it should be stopped and repaired by professional maintenance personnel It can be used only after the electrical performance index is normal Maintenance Af...

Page 15: ...g analysis and elimination solution provider Speciality Creates Value AP T Shanghai Anping Static Technology Co Ltd Tel 86 21 64517676 Fax 86 21 64517673 Postcode 200233 Website www ap static com Addr...

Reviews: