Intelligent Remote Control

Ion balance/ion output frequency adjustable

Button function instructions

Unlock

Unlock before adjusting operating parameters

Run / Pause

Device starts running when power is on. Press "STOP" to standby and no 

high voltage output.  Press "RUN" again and the device will start working.

Adjust cleaning 

cycle

CT

TH 

→ +/-

Press CT

TH

 first, then press +/- to increase or decrease the cleaning cycle. 

The default cleaning cycle is 15 days, and the adjustment range is 1-60 

days;The cleaning function will alarm and the power will be restarted to 

restore the set time when the countdown is 0 days; the cleaning function 

will be invalid when it is set to 0 days.

Adjust frequency FREQ → +/-

Press FREQ first, then press +/- to increase or decrease the output frequency 

of positive and negative ions(cycle setting). Note: This adjustment function 

can only be effective if the coding switch is in C or D position.

Adjust balance

IB

→ +/-

Press IBN first, then press + when the positive voltage on flat panel 

detector or discharge object surface is high, press IBN first, then press 

- when the negative voltage on flat panel detector or discharge object 

surface is high until the ion balance reaches the ideal status.

Confirm

CAL → OK

Note: Press CAL first, then press OK to confirm after adjusting the output 

parameter; otherwise, false alarms are likely to occur.

Reset

CAL →

Reset

Press CAL first

then press

Note:  The discharge effect will be improved if the ion balance (output) is adjusted to the opposite polarity of the charged object in the case where the static charge with a certain polarity is attached to 

the static charge removal object in advance. However, be careful not to charge the object back in this case.

Function

Symbol

Operation instructions

Summary of Contents for AP-DB1223

Page 1: ...Distant Space Static Removal Ion Bar Shanghai Anping Static Technology Co Ltd AP DB1223...

Page 2: ...oelectronics semiconductor and other industries Effectively solve the problems caused by static electricity Prevent adhesion of objects Static removal Prevent blockage of feeder Prevent static electri...

Page 3: ...c elimination device developed and produced by Anping Company to eliminate static electricity and maintain static balance in clean spaces which adopts a DC high voltage power supply and a special sili...

Page 4: ...sitive and negative ions cycle setting Note This adjustment function can only be effective if the coding switch is in C or D position Adjust balance IBN Press IBN first then press when the positive vo...

Page 5: ...discharge speed TIME Reduce the negative high voltage amplitude the negative ion output decreases Adjust ion balance voltage TIME TIME TIME Adjust ion balance voltage Increase the negative high voltag...

Page 6: ...nd its static elimination ability can be exerted no matter in short or long distance In addition the discharge frequency can be adjusted which can extend the discharge distance The output ratio of pos...

Page 7: ...city No 2 Working status indicator Green light Normal work Red light Abnormal high voltage Blue light Infrared adjustment pause cleaning indication No 3 Features Safe Easy to use Durable Electroshock...

Page 8: ...ar installed End to end connection in series to simplify wiring The product can be switched on from end to end to simplify wiring Each adapter power supply can load up to 2 space bars Features Safe Ea...

Page 9: ...Status indicator Coding switch Power connector Front Back port Three phase power socket Two middle electrodes spacing is 200mm two end electrodes spacing is 100mm RJ45 power communication port Install...

Page 10: ...djusted by remote control Ozone thickness 0 1ppm 50mm away from the emitter electrode Alarm indicator Green light Normal work Red light Abnormal high voltage Blue light Debugging cleaning indication R...

Page 11: ...function information 1 Orange 24VDC 2 White orange 24VDC 3 Blue RS485 B 4 White blue RS485 A 5 Green GND 6 White green GND 7 Brown HVAL Eliminator high voltage alarm 8 White brown ACT Eliminator power...

Page 12: ...2 6 1LML05000 M5 4 AP6620006 AP2253011 1 Packing accessories OK CTTH PWM FREQ CFM IBV IBN 1 2 3 6 5 4 IBP CAL ALTH AP T R Part name Picture Part No Specification Qty L shaped stainless steel mounting...

Page 13: ...ctric shock accidents 11 The electrode needle is a sharp metal object please use it with care 12 Please check the specifications of the power supply before powering on the product Any power supply tha...

Page 14: ...r body and the panel indicator light are off it should be stopped and repaired by professional maintenance personnel It can be used only after the electrical performance index is normal Maintenance Af...

Page 15: ...g analysis and elimination solution provider Speciality Creates Value AP T Shanghai Anping Static Technology Co Ltd Tel 86 21 64517676 Fax 86 21 64517673 Postcode 200233 Website www ap static com Addr...

Reviews: