FACTORY SETTINGS
P A R A M E T E R
F A C T O R Y
S E T T I N G
R A N G E O F
V A L U E S
Te m p e r a t u r e S e t P o i n t
7 5
o
F ( 2 3 . 9
o
C )
- 4 0 t o 9 9 . 9
o
F
( - 4 0 t o 3 7 . 7
o
C )
St a g e 1
Mi n i mum Sp e e d
4 0 %
1 0 % t o 1 0 0 %
Ti me On
1 5 s e c o n d s
0 t o 9 0 0 s e c o n d s b y
i n c r e m e n t s o f 1 5
s e c o n d s
Ti me Of f
0 s e c o n d s
B a n d w i d t h
2
o
F ( 1 . 1
o
C )
0 . 5 t o 2 0
o
F
( 0 . 3 t o 1 1 . 1
o
C )
Humi d i t y
C o n t r o l
Humi d i t y
S e t P o i n t
6 5 %
4 0 t o 1 0 0 % r e l a t i v e
h u mi d i t y
C o m p e n s a t i o n
P e r c e n t a g e
6 0 %
0 t o 1 0 0 % o f s t a g e 1
mi n i mum s p e e d
St a g e 2
D i f f e r e n t i a l
2
o
F ( 1 . 1
o
C )
0 . 5 t o 2 0
o
F
( 0 . 3 t o 1 1 . 1
o
C )
St a g e 3
Of f s e t
0 ° F ( 0 ° C )
0 t o 2 0 ° F
( 0 t o 1 1 . 1 ° C )
D i f f e r e n t i a l
2
o
F ( 1 . 1
o
C )
0 . 5 t o 2 0
o
F
( 0 . 3 t o 1 1 . 1
o
C )
C u r t a i n s
D e a d B a n d
2
o
F ( 1 . 1
o
C )
0 . 5 t o 2 0
o
F
( 0 . 3 t o 1 1 . 1
o
C )
Ti me On
2 0 s e c o n d s
0 t o 9 0 0 s e c o n d s , b y
i n c r e m e n t s o f 1
s e c o n d
Ti me Of f
8 0 s e c o n d s
Out s i d e S e t
P o i n t
7 0 ° F ( 2 1 ° C )
- 4 0 t o 9 9 . 9
o
F
( - 4 0 t o 3 7 . 7
o
C )
11
TC5-1N5FAB rev.06
TC5-1N5FAB
CAUTION:
Do not run probe cables next to other power cables. When
crossing over other cables, cross at 90°.
3
Installing the Outside Probe
n
Run the outside probe cable on the north side of the building, 6 ft (2 m)
below the eave, inside a pale colored conduit. Avoid installing the
probe in direct sunlight or exposed to the rain.
n
Be sure the probe cable is isolated from sheet metal or any other
conductive material.
n
Be sure no cable joint is exposed to air or water.
4
Defective Probes
If a defective probe is detected, the Defective Probe Pilot Light flashes. The
room temperature shown on the display is then the average temperature
measured by the probes in working condition. The controller will operate
according to this temperature.
To identify the defective probe:
n
Set the selection knob to
ROOM
TEMPERATURE
. The room tem-
perature is displayed.
n
Press the push-button. If the
probe connected to input # 1 and
supplied with the controller is not
defective, the letters"
PR1
" are dis-
played, alternating with the on/
off state of the probe and the tem-
perature measured by the probe.
If the probe is defective, the let-
ters "
PR1
" are displayed, alter-
nating with the state of the probe
and the letter "
P
".