7 . 1 1   E L E C T R O N I C   C I R C U I T   A L A R M   S I G N A L S  

 
The electronic circuit detects every cause of imperfect air filtration. If there is a slight drop in the efficiency of 
the machine, the yellow PRE-ALARM Led will light up. If, however, the drop in efficiency is greater, filtering 
will be blocked completely and the red MAINTENANCE Led will go on. These signals can also come on 
because of faults in the physical state of the electrostatic cells. 
 

 
TYPE OF ALARM 
 

 
CAUSE 

 
OPERATION 

yellow LED on 
PRE-ALARM or 
letter F on the  display 

electrostatic cell dirty 

carry out normal maintenance 

yellow LED on 
PRE-ALARM 

electrostatic cell not properly 
clean 

if small dirty areas have remained, washing must 
be carried out again 

yellow LED on 
PRE-ALARM 

electrostatic cell damp 

dry the cell thoroughly and particularly in the zone 
of the insulators 

yellow LED on 
PRE-ALARM 

electrostatic cell not properly 
rinsed 

there may be detergent on the insulators; the cell 
must be thoroughly rinsed again 

yellow LED on 
PRE-ALARM 

small bodies trapped between 
the collection blades 

the foreign bodies deposited on the blades must 
be removed 

 

 

 

red LED on 
MAINTENANCE 

electrostatic cell very dirty 

carry out normal maintenance as soon as possible 

red LED on 
MAINTENANCE and  
ALARM 

electrostatic cell very dirty 
because of breakage of an 
ionisation wire 

the wire must be removed and replaced 
immediately 

red LED on 
MAINTENANCE and  
ALARM 

electrostatic cell short circuited 
due to collection blade being 
bent 

the blade must be straightened (call a specialised 
technician) 

red LED on 
MAINTENANCE and  
ALARM 

electrostatic cell short circuited 
by body trapped between the 
blades 

the body must be removed taking care not to 
break the ionisation wires 

 

 

 

letter F on the  display 

ionisation wires dirty or oxidised  clean the wires with a rag soaked in alcohol; if the 

problem persists, the wires must be replaced 

 
 
It is possible that the operating status of the Revitalizer can be modified with some infrared remote control 
units for television sets or banknote readers for videogames by modifying the speed fan and the status of the 
machine. Check that this does not happen by pointing the TV remote control at the Revitalizer and press the 
ON/OFF button. 

Summary of Contents for LifePro50p

Page 1: ...AIR QUALITY MOBILE 50P Jan 2012 Automatikprodukter USERS MANUAL AND INSTALLATION GUIDE...

Page 2: ...AIR QUALITY MOBILE 50P Jan 2012 Automatikprodukter...

Page 3: ...1 Access Door 13 5 1 2 Washing the filters 14 5 2 GENERAL INSPECTION OF THE FILTERS 15 5 3 CLEANING THE MACHINE 15 6 AVAILABLE VERSIONS 16 7 NATURE SYSTEM 18 7 1 CONTROL PANEL 19 7 1 1 DISPLAY 19 7 1...

Page 4: ...IRCUIT ALARM SIGNALS 32 8 10 ELECTRONIC CIRCUIT ANOMALOUS SIGNALS 33 9 BASIC SYSTEM 34 9 1 CONTROL PANEL 35 9 2 VISUALISATION OF SPEED 35 9 2 1 RECEIVER 35 9 2 2 MANUAL AND ON OFF FILTER BUTTONS 36 9...

Page 5: ...M A C H I N E identification plate There is a plate in every machine showing the model and the series number which identify the machine This plate is located on the inside of the machine and it is the...

Page 6: ...M A R K I N G O F T H E M A C H I N E The EC conformity mark is located on the control panel of the machine 1 2 1 O p e n i n g t h e d o o r For opening the door it is necessary to introduce a finger...

Page 7: ...nary maintenance or repairs The following objects should be found in the box the required machine users manual and guarantee leaflet remote control unit plug 2 2 T R A N S P O R T To limit damage and...

Page 8: ...A T I O N O F T H E M A C H I N E For a correct function place the machine so that the air can fulfil the cycle as figured on the picture The air that comes out of the hinder air diffuser must not fin...

Page 9: ...o the average number of people present in them To calculate the quantity of air in m3 h to introduce from the exterior it is sufficient to multiply the average number of persons present by a coefficie...

Page 10: ...llutant particles with an efficiency of 99 Its dimensions vary depending on the model it is fitted in DIMENSIONS FILTER MODEL A B C 50p 344 310 115 The cell is built entirely in anticorodal aluminium...

Page 11: ...electrical connection is made between the electronic circuit and the electrostatic cell During maintenance inspect to ensure that the flexible arches are intact Also ensure that there are no burns or...

Page 12: ...THE MACHINE 4 2 1 E l e c t r o n i c c i r c u i t p r o t e c t i o n d e v i c e s The electronic circuit is provided with a series of protection devices which automatically cut off the high voltag...

Page 13: ...ion of the machine Extraordinary maintenance is carried out by specialised personnel 5 1 F I L T E R M A I N T E N A N C E To carry out filter maintenance it is necessary to gain access to them throug...

Page 14: ...the filters 4 Vinegar Prepare the tray with the raised bottom with warm water max 45 C Dilute the detergent in the proportions indicated on the label of the detergent itself Put the vinegar and water...

Page 15: ...H E F I L T E R S The state of the filters must be inspected every time they are washed so as to prevent air cleaner malfunction and problems INSPECTION FAULT OPERATION ionisation wires breakage of a...

Page 16: ...librium inside a confined environment as close as possible to the ideal one for well being ENVIRONMENTAL REVITALIZER RIVITALIZZATORE AMBIENTALE Identifies the apparatus which in an equilibrated manner...

Page 17: ...esture in complete autonomously way the parameters of the filtration depending from the chosen performance of function and the level of saturation of the electrostatic cell HIGH EFFICIENCY FILTERING I...

Page 18: ...operating status of the apparatus Infrared remote control unit The remote control unit allows the user to control the operation of the Revitalizer from a distance of about 6 7 metres in particular th...

Page 19: ...erating air flow 0 1 2 3 If on the other hand the letter F appears this means that operation of the electrostatic cell is not correct The reason may be a deposit of pollutant on the surface of the ion...

Page 20: ...o completely dry the filtering unit after washing or to use the machine for the ventilation function only The RESET button is for turning off the ALARM signal if the circuit protection device has trip...

Page 21: ...enance flow room half empty sets the normal use flow room half full sets the emergency flow room crowded turns off the air purifier How to use point the remote control towards the control panel taking...

Page 22: ...re Reduction Cardiovascular system Improvement Metabolism Increase Allergies Reduction Respiratory capacity Improvement Insomnia Reduction Mental concentration Increase The Revitalizer only goes off w...

Page 23: ...ing phase by turning the Revitalizer to one of the 3 speeds available by means of the remote control unit or the MANUAL button 7 8 S I G N A L S The electronic control of this apparatus provides the u...

Page 24: ...bars casinos discos pubs amusement arcades etc TYPE B suitable for premises such as restaurants pizzeria cafes ice cream parlours butcher shops etc TYPE C suitable for premises such as shops and store...

Page 25: ...ain yellow LED on PRE ALARM small bodies trapped between the collection blades the foreign bodies deposited on the blades must be removed red LED on MAINTENANCE electrostatic cell very dirty carry out...

Page 26: ...ate when the Revitalizer is working The other two cases are due to activation of particular test programs due to the simultaneous pressure of two buttons on the control panel of the circuit To elimina...

Page 27: ...information required on the operating status of the apparatus Infrared remote control unit The remote control unit allows the user to control the operation of the machine from a distance of about 6 7...

Page 28: ...flow 0 1 2 3 If on the other hand the letter F appears this means that operation of the electrostatic cell is not correct The reason may be a deposit of pollutant on the surface of the ionisation wire...

Page 29: ...ed when you need to completely dry the filtering unit after washing or to use the machine for the ventilation function only The RESET button is for turning off the ALARM signal if the circuit protecti...

Page 30: ...the normal use flow room half full sets the emergency flow room crowded turns off the air purifier How to use point the remote control towards the control panel taking care that you are in line with i...

Page 31: ...EST ON OFF FILTER buttons 8 8 S T A T E O F F I L T R A T I O N E F F I C I E N C Y As described in paragraph CONTROL PANEL the three Leds of FILTRATION STATUS provide indications on the state of filt...

Page 32: ...gain yellow LED on PRE ALARM small bodies trapped between the collection blades the foreign bodies deposited on the blades must be removed red LED on MAINTENANCE electrostatic cell very dirty carry ou...

Page 33: ...llate when the machine is working The other two cases are due to activation of particular test programs due to the simultaneous pressure of two buttons on the control panel of the circuit To eliminate...

Page 34: ...tive ionisation along with the information required on the operating status of the apparatus Infrared remote control unit The remote control unit allows the user to control the operation of the machin...

Page 35: ...ices which permit manual operation and visual control of the operating conditions are given here below 9 2 V I S U A L I S A T I O N O F S P E E D 9 2 1 R E C E I V E R The receiver permits the recept...

Page 36: ...I T The remote control unit allows you to control the machine modifying the air flow from a distance of about 6 7 metres The following functions are provided How to use point the remote control towar...

Page 37: ...can be resolved by a small operation TYPE OF ALARM CAUSE OPERATION green Led FILTER OK is flashing electrostatic cell dirty carry out normal maintenance electrostatic cell not properly clean if small...

Page 38: ...used to build them 1 1 1 C E R T I F I C A T I O N C N R The machines are in possession of C N R certification which attests to the efficiency of filtration declared for each model and certifies that...

Reviews: