1 9
8.4 Section 1. Configuration of AL
Table 8.1
Section
AL’s
number
n
Parameter’s code
and name
Parameter’s
value
Description
AL operation algorithm
11
without verification (
by default
)
12
with verification
1
n
1
13
Two detectors’ trigger
1
n
2
Fixation of AL basic current
AL type
11
combined (
by default
)
12
active
13
passive
21
combined –
passive
detector trigger priority
22
combined –
active
detector trigger priority
1
n
3
24
disabled
AL reset time
11
5 sec (
by default
)
12
10 sec
13
15 sec
14
20 sec
21
25 sec
22
30 sec
23
35 sec
1
n
4
24
40 sec
AL verification time
11
10 sec
12
20 sec
13
30 sec
14
40 sec
21
60 sec (
by default
)
22
120 sec
23
180 sec
1
n
5
24
240 sec
Current growth threshold to identify active detector trigger
11
1,0 m
12
2,0 m
13
3,0 m
14
4,0 m (
by default
)
21
5,0 m
22
6,0 m
23
7,0 m
1
n
6
24
8,0 m
Current decrease threshold to identify passive detector
trigger
11
0,8 m
12
1,2 m (
by default
)
13
1,6 m
14
2,0 m
21
2,4 m
22
2,8 m
1
n
7
23
3,2 m