background image

 

 

 

 

 

CE TEST REPORT

 

 

Report No. : C121401

 

SPORTON International Inc.

 

Page Number 

:  42 of 62 

TEL : 886-2-2696-2468 

Issued Date 

:  Feb. 21, 2001 

FAX : 886-2-2696-2255 

 

11.  Electrical Fast Transient/Burst Immunity Test (EFT/BURST) 

 

?

?

Pass Performance Criteria 

:  A 

?

?

Basic Standard 

:  EN 61 000-4-4:1995 

?

?

Generic Standard 

:  EN 55024:1998 

?

?

Level 

:  on Power Supply --  2 

?

?

Tested voltage 

:  on Power Supply -- 0.5/1.0 KV 

?

?

Temperature 

:  20

?

?

?

Relative Humidity 

:  49% 

?

?

Test Date 

:  Feb. 16, 2001 

11.1  Test setup 

 

Summary of Contents for CDRW121032A

Page 1: ...1996 EN61000 4 4 1995 EN61000 4 5 1995 EN61000 4 6 1996 EN61000 4 8 1993 EN61000 4 11 1994 Equipment CD RW Model No CRW1232 PRO CDRW121032A Applicant AOpen Inc 24F 100 Sec 1 Hsin Tai Wu Rd Hsichih Tai...

Page 2: ...Test Setup Layout of Conducted Powerline 13 5 4 Test Result of AC Powerline Conducted Emission 14 5 5 Photographs of Conducted Powerline Test Configuration 16 6 Test of Radiated Emission 18 6 1 Descr...

Page 3: ...TEST LEVEL 48 12 3 TEST PROCEDURE 48 12 4 OPERATING CONDITION 49 12 5 Photographs of SURGE IMMUNITY TEST 50 13 CONDUCTED DISTURBANCES INDUCED BY RADIO FREQUENCY FIELD IMMUNITY TEST CS 51 13 1 TEST LEV...

Page 4: ...icant AOpen Inc 24F 100 Sec 1 Hsin Tai Wu Rd Hsichih Taipei Hsien 221 Taiwan R O C I HEREBYCERTIFY THAT The measurements shown in this test report were made in accordance with the procedures given in...

Page 5: ...24F 100 Sec 1 Hsin Tai Wu Rd Hsichih Taipei Hsien 221 Taiwan R O C 1 2 Manufacturer Same as 1 1 1 3 Basic Description of Equipment under Test Equipment CD RW Model No CRW1232 PRO CDRW121032A Trade Nam...

Page 6: ...onitor DELL PS 2 Keyboard PRIMAX PS 2 Mouse KOKA Headset and EUT were connected to the AOpen PC for EMS test d Frequency range investigated conduction 150 KHz to 30 MHz radiation 30 MHz to 1000MHz 2 2...

Page 7: ...EX FCC ID IFAXDM1414 Model No DM1414 Power Supply Type Linear Power Cord Non Shielded Serial No SP0015 Data Cable Shielded 360 degree via metal backshells 1 15m Support Unit 6 Earphone J S FCC ID N A...

Page 8: ...2 PS 2 Keyboard DELL FCC ID GYUM92SK Model No AT101 DE8M Serial No SP0054 Data Cable Shielded 1 9m Support Unit 3 PS 2 Mouse PRIMAX FCC ID EMJMUSJQ Model No MUS9J Serial No SP0045 Data Cable Shielded...

Page 9: ...s the test program from the floppy disk drive and runs it c The PC sends H messages to the monitor and the monitor displays H patterns on the screen d The PC sends H messages to the printer then the p...

Page 10: ...EMS Test European Standard EN 55 024 1998 ESD EN 61 000 4 2 RS EN 61 000 4 3 EFT EN 61 000 4 4 SURGE EN 61 000 4 5 CS EN 61 000 4 6 Power Frequency Magnetic Field EN 61 000 4 8 DIPS EN 61 000 4 11 4...

Page 11: ...g to the methods defined in European Standard EN 55022 Clause 9 The EUT was placed on a nonmetallic stand in a shielded room 0 8 meters above the ground plane as shown in section 5 3 The interface cab...

Page 12: ...ect to the other LISN d The LISN provides 50 ohm coupling impedance for the measuring instrument e The CISPR states that a 50 ohm 50 microhenry LISN should be used f Both sides of AC line were checked...

Page 13: ...No C121401 SPORTON International Inc Page Number 13 of 62 TEL 886 2 2696 2468 Issued Date Feb 21 2001 FAX 886 2 2696 2255 5 3 Typical Test Setup Layout of Conducted Powerline L I S N 10 cm 80 cm to th...

Page 14: ...NE 24 771 MHz 37 10 dBuV Freq Line Meter Reading Limits Margin or Q P A V Q P A V Q P A V Q P A V Q P A V MHz Neutral dBuV dBuV uV uV dBuV dBuV uV uV dB dB 0 157 L 49 80 19 10 309 03 9 02 65 62 55 62...

Page 15: ...eq Line Meter Reading Limits Margin or Q P A V Q P A V Q P A V Q P A V Q P A V MHz Neutral dBuV dBuV uV uV dBuV dBuV uV uV dB dB 0 156 L 50 10 19 50 319 89 9 44 65 67 55 67 1921 82 607 73 15 6 36 2 1...

Page 16: ...Page Number 16 of 62 TEL 886 2 2696 2468 Issued Date Feb 21 2001 FAX 886 2 2696 2255 5 5 Photographs of Conducted Powerline Test Configuration The photographs show the configuration that generates th...

Page 17: ...21401 SPORTON International Inc Page Number 17 of 62 TEL 886 2 2696 2468 Issued Date Feb 21 2001 FAX 886 2 2696 2255 The photographs show the configuration that generates the maximum emission WRITE NE...

Page 18: ...shown in section 6 3 The interface cables and equipment positions were varied within limits of reasonable applications to determine the positions producing maximum radiated emissions 6 1 Description o...

Page 19: ...meters above ground to find the maximum value of the field strength both horizontal polarization and vertical polarization of the antenna are set to make the measurement e For each suspected emission...

Page 20: ...ON International Inc Page Number 20 of 62 TEL 886 2 2696 2468 Issued Date Feb 21 2001 FAX 886 2 2696 2255 6 3 Typical Test Setup Layout of Radiated Emission Antenna 0 8 M Equipment under Test FRP Room...

Page 21: ...ss Reading Emission The Radiated Emission test was passed at minimum margin VERTICAL 48 900 MHz 26 30 dBuV Antenna Height 1 Meter Turntable Degree 25 o Frequency Antenna Cable Reading Limits Emission...

Page 22: ...Radiated Emission test was passed at minimum margin VERTICAL 586 400 MHz 32 58 dBuV Antenna Height 1 5 Meter Turntable Degree 225 o Frequency Antenna Cable Reading Limits Emission Level Margin Polari...

Page 23: ...c Page Number 23 of 62 TEL 886 2 2696 2468 Issued Date Feb 21 2001 FAX 886 2 2696 2255 6 5 Photographs of Radiated Emission Test Configuration The photographs show the configuration that generates the...

Page 24: ...21401 SPORTON International Inc Page Number 24 of 62 TEL 886 2 2696 2468 Issued Date Feb 21 2001 FAX 886 2 2696 2255 The photographs show the configuration that generates the maximum emission WRITE NE...

Page 25: ...2 Test Procedure The measured values of the harmonics components of the input current including line current and neutral current shall be compared with the limits given in Clause 7 of EN 61000 3 2 7...

Page 26: ...ued Date Feb 21 2001 FAX 886 2 2696 2255 7 5 Current Harmonics Test 7 5 1 Test Data Of Current Harmonics FINAL TEST RESULT PASS Fundamental Current 0 261 A Real Power 61 5 W Power Factor 0 508 Percent...

Page 27: ...CE TEST REPORT Report No C121401 SPORTON International Inc Page Number 27 of 62 TEL 886 2 2696 2468 Issued Date Feb 21 2001 FAX 886 2 2696 2255 7 5 2 Test Graph Of Harmonics...

Page 28: ...of the test circuit excluding the appliance under test but including the internal impedance of the supply source shall be equal to the reference impedance The stability and tolerance of the reference...

Page 29: ...2001 FAX 886 2 2696 2255 8 5 Test Result Of Voltage Fluctuation And Flicker Test 8 5 1 Test Data Of Voltage Fluctuation And Flicker FINAL TEST RESULT PASS Temperature 20 Relative Humidity 49 RH Test D...

Page 30: ...CE TEST REPORT Report No C121401 SPORTON International Inc Page Number 30 of 62 TEL 886 2 2696 2468 Issued Date Feb 21 2001 FAX 886 2 2696 2255 8 5 2 Test Graph Of Voltage Fluctuation And Flicker...

Page 31: ...ort No C121401 SPORTON International Inc Page Number 31 of 62 TEL 886 2 2696 2468 Issued Date Feb 21 2001 FAX 886 2 2696 2255 8 6 Photographs Of Harmonics Test Voltage Fluctuation And Flicker Test FRO...

Page 32: ...ture 16 C Relative Humidity 45 Test Date Feb 16 2001 9 1 Test setup The test setup consists of the test generator EUT and auxiliary instrumentation necessary to perform DIRECT and INDIRECT application...

Page 33: ...ing system The EUT was arranged and connected according to its functional requirements A distance of 1m minimum was provided between the EUT and the wall of the lab and any other metallic structure In...

Page 34: ...successive single discharges an initial value of one second is recommended Longer intervals may be necessary to determine whether a system failure has occurred f In the case of contact discharges the...

Page 35: ...sued Date Feb 21 2001 FAX 886 2 2696 2255 9 4 Test Severity Levels 9 4 1 Contact Discharge Level Test Voltage KV of Contact discharge 1 2 2 4 3 6 4 8 X Specified Remark X is an open level 9 4 2 Air Di...

Page 36: ...2468 Issued Date Feb 21 2001 FAX 886 2 2696 2255 9 5 Test Points 9 5 1 Test Result of Air Discharge Test Point Voltage Tested No Observation Result Case 2 4 8 KV BY 10 NORMAL PASS Earphone jack 2 4 8...

Page 37: ...Tested No Observation Result Horizontal At Front 2 4 KV BY 25 NORMAL PASS Horizontal At Left 2 4 KV BY 25 NORMAL PASS Horizontal At Right 2 4 KV BY 25 NORMAL PASS Horizontal At Rear 2 4 KV BY 25 NORMA...

Page 38: ...ORT Report No C121401 SPORTON International Inc Page Number 38 of 62 TEL 886 2 2696 2468 Issued Date Feb 21 2001 FAX 886 2 2696 2255 9 6 Photographs of Electrostatic Discharge Immunity Test FRONT VIEW...

Page 39: ...The SPORTON 7m x 4m x 4m semichoic chamber is compliance with the sixteen points uniform field requirement as stated in IEC 1000 4 3 Section 6 2 The procedure defined in this part requires the generat...

Page 40: ...justing the continuous wave to the applicable antennae c The test is normally performed with the antenna facing the most sensitive side of the EUT The polarization of the field generated by the biconi...

Page 41: ...ort No C121401 SPORTON International Inc Page Number 41 of 62 TEL 886 2 2696 2468 Issued Date Feb 21 2001 FAX 886 2 2696 2255 10 4 Photographs of Radio Frequency Electromagnetic Field Immunity Test FR...

Page 42: ...2001 FAX 886 2 2696 2255 11 Electrical Fast Transient Burst Immunity Test EFT BURST Pass Performance Criteria A Basic Standard EN 61 000 4 4 1995 Generic Standard EN 55024 1998 Level on Power Supply 2...

Page 43: ...T It was connected to the protective grounding system The EUT was arranged and connected according to its functional requirements The minimum distance between the EUT and other conductive structures e...

Page 44: ...boratory shall not influence the test results c The variety and diversity of equipment and systems to be tested make it difficult to establish general criteria for the evaluation of the effects of fas...

Page 45: ...evels are recommended for the fast transient burst test Open circuit output test voltage 10 Level On Power Supply On I O signal data and control line 1 0 5 KV 0 25 KV 2 1 0 KV 0 50 KV 3 2 0 KV 1 00 KV...

Page 46: ...Report No C121401 SPORTON International Inc Page Number 46 of 62 TEL 886 2 2696 2468 Issued Date Feb 21 2001 FAX 886 2 2696 2255 11 6 Photographs of Electrical Fast Transient BURST Immunity Test FRONT...

Page 47: ...Standard EN 61 000 4 5 1995 Generic Standard EN 55 024 1998 Input Voltage Frequency 230Vac 50Hz Level 3 Test Voltage 1 0 2 0 KV Temperature 19 C Relative Humidity 51 Test Date Feb 16 2001 12 1 TEST RE...

Page 48: ...humidity 10 to 75 atmospheric pressure 86 kPa to 106 kPa 860 mbar to 1060 mbar b Electromagnetic conditions The electromagnetic environment of the laboratory shall not influence the test results c Th...

Page 49: ...rrent voltage characteristics of the equipment under test Therefore the test voltage has to be increased by steps up to the test level specified in the product standard or test plan g All lower levels...

Page 50: ...TEST REPORT Report No C121401 SPORTON International Inc Page Number 50 of 62 TEL 886 2 2696 2468 Issued Date Feb 21 2001 FAX 886 2 2696 2255 12 5 Photographs of SURGE IMMUNITY TEST FRONT VIEW REAR VI...

Page 51: ...ria A Basic Standard EN 61 000 4 6 1996 Generic Standard EN 55 024 1998 Input Voltage Frequency AC 230V 50Hz Level 2 Test Voltage 3 V rms Modulated 1KHz 80 AM Frequency Range 0 15 MHz to 80 MHz Temper...

Page 52: ...sing the signal levels established during the setting process and with the disturbance signal 80 amplitude modulated with a 1KHz sinewave pausing to adjust the RF signal level or to switch coupling de...

Page 53: ...0 4 8 1993 Generic Standard EN 55 024 1998 Input Voltage Frequency AC 230V 50Hz Temperature 19 C Relative Humidity 51 Test Date Feb 16 2001 14 1 TEST RECORD Power Frequency Magnetic Field Testing dura...

Page 54: ...Report No C121401 SPORTON International Inc Page Number 54 of 62 TEL 886 2 2696 2468 Issued Date Feb 21 2001 FAX 886 2 2696 2255 14 4 Photographs of Power Frequency Magnetic Field immunity tests FRONT...

Page 55: ...ge dips Basic Standard EN 61 000 4 11 1994 Generic Standard EN 55 024 1998 Input Voltage Frequency AC 230V 50Hz Temperature 19 C Relative Humidity 51 Test Date Feb 16 2001 15 1 TEST RECORD OF VOLTAGE...

Page 56: ...st was based on EN 61 000 4 11 1994 15 4 TEST CONDITIONS 1 Source voltage and frequency 230V 50Hz Single phase 2 Test of interval 10 sec 3 Level and duration Sequency of 3 dips interrupts 4 Voltage ri...

Page 57: ...rt No C121401 SPORTON International Inc Page Number 57 of 62 TEL 886 2 2696 2468 Issued Date Feb 21 2001 FAX 886 2 2696 2255 15 6 Photographs of VOLTAGE DIPS AND VOLTAGE INTERRUPTIONS IMMUNITY TESTS F...

Page 58: ...6 6 1 1 70 7 2 1 2 75 7 7 1 2 80 8 4 1 2 85 8 6 1 3 90 8 8 1 2 95 9 3 1 3 100 9 7 1 3 110 11 6 1 4 120 13 3 1 4 130 13 8 1 6 140 13 6 1 5 150 12 1 1 6 160 10 1 1 6 170 9 5 1 7 180 9 5 1 8 190 9 7 1 9...

Page 59: ...nduction LISN KYORITSU KNW 407 8 1010 15 50uH 50 ohm Nov 13 2000 Conduction Power Filter CORCOM MR12030 N A 30A 2 N A Conduction Spectrum Analyzer site1 HP 8568B 2928A04713 100 Hz 1 5 GHz May 06 2000...

Page 60: ...ontroller EMCAutomation VCC 01 N A N A RS Signal Generator HP 8648A 100 KHz 1 GHz Sep 10 2000 RS Signal Generator R S SMX 100 KHz 1 GHz Nov 06 2000 RS Antenna CHASE CBL6121A 26 MHz 1 GHz Jun 12 2000 R...

Page 61: ...ss B product this notice should be disregarded Class A ITE is a category of all other ITE which satisfies the class A ITE limits but not the class B ITE limits Such equipment should not be restricted...

Page 62: ...urer or His Authorized Representative Established within the Community or by an Importer Following Testing of the Product and Issued of an EC certificate of conformity by a competent body Article 10 2...

Reviews: