CE TEST REPORT
Report No. : C121401
SPORTON International Inc.
Page Number
: 10 of 62
TEL : 886-2-2696-2468
Issued Date
: Feb. 21, 2001
FAX : 886-2-2696-2255
4. General Information of Test
4.1 Test Facility
< EMI >
This test was carried out by SPORTON International Inc.
Test Site Location
: No. 3, Lane 238, Kang Lo Street, Nei Hwu District,
Taipei 11424, Taiwan, R.O.C.
TEL : 886-2-2631-4739
FAX : 886-2-2631-9740
< EMS >
This test was carried out by SPORTON International Inc.
Test Site Location
: No. 30-2, Lin 6, Diing-Fwu Tsuen, Lin-Kou-Hsiang,
Taipei Hsien, Taiwan, R.O.C.
TEL : 886-2-2601-1640
FAX : 886-2-2601-1695
4.2 Standard for Methods of Measurement
EMI Test (conduction and radiation) : European Standard EN 55022 Class B
Harmonics Test
: European Standard EN 61000-3-2.
Voltage Fluctuations Test
: European Standard EN 61000-3-3.
EMS Test
: European Standard EN 55 024:1998.
(ESD: EN 61 000-4-2, RS: EN 61 000-4-3, EFT: EN 61 000-4-4, SURGE: EN 61 000-4-5,
CS: EN 61 000-4-6, Power Frequency Magnetic Field: EN 61 000-4-8, DIPS: EN 61 000-4-11)
4.3 Test in Compliance with
EMI Test (conduction and radiation) : European Standard EN 55022 Class B
Harmonics Test
: European Standard EN 61000-3-2.
Voltage Fluctuations Test
: European Standard EN 61000-3-3.
EMS Test
: European Standard EN 55 024:1998.
(ESD: EN 61 000-4-2, RS: EN 61 000-4-3, EFT: EN 61 000-4-4, SURGE: EN 61 000-4-5,
CS: EN 61 000-4-6, Power Frequency Magnetic Field: EN 61 000-4-8, DIPS: EN 61 000-4-11)
4.4 Frequency Range Investigated
a. Conducted emission test: from 150 kHz to 30 MHz
b. Radiated emission test: from 30 MHz to 1,000 MHz
c. Radio frequency electromagnetic field immunity test : 80-1000 MHz.
4.5 Test Distance
The test distance of radiated emission test from antenna to EUT is 10 M.
The test distance of radio frequency electromagnetic field immunity test from antenna to EUT is 3 M.