CE TEST REPORT
Report No. : C121401
SPORTON International Inc.
Page Number
: 28 of 62
TEL : 886-2-2696-2468
Issued Date
: Feb. 21, 2001
FAX : 886-2-2696-2255
8. Voltage Fluctuations Test
8.1 Standard
??
Standard
: EN 61000-3-3:1995/A1:1998
8.2 Test Procedure
The equipment shall be tested under the conditions of
Clause 5.
The total impedance of the test circuit, excluding the appliance under test, but including the internal
impedance of the supply source, shall be equal to the reference impedance. The stability and tolerance of
the reference impedance shall be adequate to ensure that the overall accuracy of
?
8% is achieved during the
whole assessment procedure.
8.3 Test Equipment Settings
??
Line Voltage : 230 V
??
Line Frequency : 50 Hz
??
Measurement Delay : 10.0 seconds
??
Pst Integration Time : 10 minutes
??
Pst Integration Periods : 1
??
Test Duration : 00:10:00 minutes
8.4 Test Setup