-BSK4117M**1K 7/9-
LINK (Green)
IN (Orange)
ALM (Red)
LINK
(Green)
LINK
ALM
IN
(Orange)
Name
Indication status
ALM
(Red)
Details
Transmission signal is appropriately supplied
Sensing level drop*
Slave unit voltage drop
Transmission signal error
No transmission signal
Normal
When the master unit found that
the ID (address) of this unit is duplicate
or is not set.
ON
OFF
Flashing
On
Flashing
(On for 0.2 seconds,
off for 1.0 second)
(0.1 seconds alternately)
Alternate flashing
On
Off
Off
On
Off
Teaching abnormality
Flashing
LINK
ALM
* Only when alarm diagnosis function is enabled
■
Setting for operation mode change
■
Setting for delay timer value
■
Setting for delay timer ON/OFF
If you set the delay timer in parameter 10, you can set the delay time.
Set if there is an alarm diagnosis function.
Variable
Details
0
Simple mode
Alarm diagnosis function disabled
Alarm diagnosis function enabled
1
Normal mode
- Address writer (ARW-04, ARW-03): Parameter 07
Default: 0
Variable
Details
0
No delay timer
Delay timer disabled
1
2
3
ON delay timer
ON/OFF delay timer
ON/OFF delay timer enabled
OFF delay timer
ON delay timer enabled
OFF delay timer enabled
- Address writer (ARW-04, ARW-03): Parameter 10
Default: 0
Set the ON delay timer/OFF delay timer.
0 - 255
Default: 0
- Address writer (ARW-04, ARW-03): Parameter 11
■
Normally open/Normally close setting
Variable
Details
0
Normally open
ON with work present
Set the normally open/normally close.
1
Normally close
ON with work absent
■
Alarm value Hi setting
■
Alarm value monitor time setting
■
Alarm value Lo setting
Set an upper limit for the alarm judgment value.
Set a lower limit for the alarm judgment value.
Set a monitor time for the alarm judgment value.
* Set the alarm values so that Hi is greater than Lo.
* Set the alarm values so that Hi is greater than Lo.
Default: 80
- Address writer (ARW-04, ARW-03): Parameter 03
Default: 50
- Address writer (ARW-04, ARW-03): Parameter 04
- Address writer (ARW-04, ARW-03): Parameter 05
- Address writer (ARW-04, ARW-03): Parameter 06
Variable
0 - 100
Unit
%
Variable
0 - 100
Unit
%
Variable
3 - 255
Unit
100ms
Default: 0
Variable
Unit
10ms
Default: BS-K4117-M12-1K : 19
BS-K4117-M18-1K : 25
BS-K4117-M30-1K : 27
CAUTION
!
Parameters [08, 09, 12 to 19] are items related to
internal settings. Do not perform settings.
[Monitor display]
Displays the operation status of this product using the LEDs.
Normal state: LINK flashing, ALM off, IN ON on/OFF off