22
|
ANYLOAD OCS Series Electronic Crane Scale User’s Guide
o
The input tare weight must be lesser than scale’s maximum capacity
otherwise an error message
will display
RESOLUTION SWITCH
Action
o
To switch scale’s resolution, press
and then
on remote
controller. This function can be done using the remote controller.
Function
o
The screen will flash the resolutions to change in descending order like
5kg, 2kg, 1kg (available options are ranging from 0.01 kg or lb to 50 kg
or lb depending on scale’s capacity). After
RESOLUTION SWITCH
, the
new resolution will take effect. (Note, for some models this function
will work temporarily. It will go back to its default system unit once the
scale has restarted. To permanently set your desired measurement
unit as the system unit you must recalibrate the scale and set your
measurement unit as the system unit. Refer to Technical Manual on
setting system unit and recalibration).
o
To balance between accuracy and measurement speed in high
resolution mode, the
ANTI‐MOTION LEVEL
can be changed to fit your
measurement application.
NOTE:
Tare setting will reduce the overloading range of the scale.
For example if a 1000kg is set by tare set functionon a 5000kg maximum
capacity scale, the new overload limit will become at 4009kg [(5000 – 1000) + 9
divisions].
NOTE:
Setting or changing TARE will not effect on the ZERO setting