7
allowing the machine to be powered down without losing function settings. The control buttons are:
FUNCTION, Up, Down, TIMER, VOLUME and MANUAL. You can program the necessary menu settings
with the control panel when the display indicates »Ready To Haze«.
After switching on, the display shortly indicates »Antari Hz-500« and is ready for haze output. The display
indicates »Ready To Haze«.
-Continuous operation
When the machine is ready for haze output, short actuation of the button VOLUME activates continuous
haze output. The display indicates »Working«. To stop the haze output, press the button VOLUME once
again.
-Manual operation
For immediate haze output, keep the button MANUAL pressed. The display indicates »Working«. As
soon as you release the button, the haze output will stop. The manual operation will take priority over the
continuous operation and the timer operation. Even if one of these operating modes is activated, the
haze machine will always emit haze when the button MANUAL is pressed.
-Timer operation
In the timer mode, the haze machine will automatically emit haze. The time intervals, duration and haze
volume depends on the corresponding menu settings. Press the button TIMER, to activate the timer
mode. The display indicates the set time interval. The unit counts down to 0 seconds and emits haze. To
deactivate the timer mode, press the button TIMER again.
-Menu settings with the button FUNCTION
1.
Setting time intervals for timer operation
Press the button FUNCTION until the display indicates »Interval Set«. Use the buttons UP and DOWN to
adjust the intervals between the individual fog outputs in timer mode within the range of 1 and 200
seconds.
2.
Setting the output duration for timer operation
Press the button FUNCTION until the display indicates »Duration Set«. Use the buttons UP and DOWN
to adjust the duration of the fog outputs in timer mode within the range of 1 and 200 seconds.