B-3 Operation Error Messages
Error Messages
B-4
PN: 10580-00207 Rev. E
BTS Master UG
Fatal error, no SPA board connected
Hardware communications between modules has failed. Insure that the battery level is
adequate for operation or that temperature is within acceptable limits. Reset to factory
defaults with either Factory Defaults, ESC+ON, or MASTER RESET, ON. Caution:
Use of MASTER RESET, ON, will erase all user saved setups and measurement
traces and return the unit to a fully Factory Default condition. If the error persists, contact
your Anritsu Service Center.
Operation not Permitted in Recall Mode
Attempted to perform an operation on a recalled trace. Many operations are valid only on a
live or active trace.
Cannot change scale in Linear mode
Linear display mode of operation does not support a scaling change in the same manner as
the Log display mode.
Cannot turn on delta marker because Ref Marker is invalid
Delta markers cannot be enabled unless the primary marker is within the displayed span.
Cannot turn on delta marker because Ref Marker is a counter Marker
Delta markers cannot be enabled unless the primary marker is NOT a counter Marker. Turn
off the Counter Marker mode of marker operation to use Delta Marker.
Current Marker is not ON
Attempted to use a marker mode or feature for a marker that is not enabled. Turn on the
appropriate marker to use this function or switch to a marker that is already enabled.
Marker must be ON to Use the feature
Attempted to use a marker mode or feature for a marker that is not enabled. Turn on the
appropriate marker to use this function or switch to a marker that is already enabled.
Triggering valid only in Zero Span
External triggering can only be used while the SPAN is set to 0 (zero)
Cannot change Modes for Recalled/Inactive Traces
Detection modes or other elements such as RBW/VBW, averaging, and so forth, cannot be
altered on a recalled trace. The trace is displayed with the same parameters in which it was
saved.
Cannot change average for Recalled/Inactive Traces
Cannot set Delta Detection modes or other elements such as RBW/VBW, averaging, and so
forth, cannot be altered on a recalled trace. The trace is displayed with the same parameters
in which it was saved.
Pretune Calibration Table fault
Ensure that the battery level is adequate for operation or that temperature is within
acceptable limits. Reset to factory defaults with either Factory Defaults, ESC+ON, or
MASTER RESET, ON. Caution: Use of MASTER RESET, ON, will erase all
user saved setups and measurement traces and return the unit to a fully Factory Default
condition. If the error persists, contact your Anritsu Service Center.
Summary of Contents for BTS Master MT8221B
Page 1: ...BTS Master User Guide MT8221B and MT8222B The High Performance Handheld Base Station Analyzer ...
Page 2: ......
Page 4: ......
Page 6: ......
Page 8: ......
Page 24: ...1 12 Secure Environment Workplace General Information 1 10 PN 10580 00207 Rev E BTS Master UG ...
Page 46: ...2 13 Firmware Overview Instrument Overview 2 22 PN 10580 00207 Rev E BTS Master UG ...
Page 54: ...3 8 PN 10580 00207 Rev E BTS Master UG ...
Page 88: ...7 8 PN 10580 00207 Rev E BTS Master UG ...
Page 94: ...8 5 Updating Instrument Firmware Master Software Tools 8 6 PN 10580 00207 Rev E BTS Master UG ...
Page 95: ...Master Software Tools 8 5 Updating Instrument Firmware BTS Master UG PN 10580 00207 Rev E 8 7 ...
Page 96: ...8 5 Updating Instrument Firmware Master Software Tools 8 8 PN 10580 00207 Rev E BTS Master UG ...
Page 97: ...Master Software Tools 8 5 Updating Instrument Firmware BTS Master UG PN 10580 00207 Rev E 8 9 ...
Page 114: ...C 8 PN 10580 00207 Rev E BTS Master UG ...
Page 118: ...Index 4 PN 10580 00207 Rev E BTS Master UG ...
Page 152: ...2 18 Other Menus GSM GPRS EDGE Signal Analyzer 2 18 PN 10580 00234 Rev V 3GPP MG ...
Page 196: ...3 18 Other Menus W CDMA HSPA Signal Analyzer 3 44 PN 10580 00234 Rev V 3GPP MG ...
Page 224: ...4 16 Other Menus TD SCDMA HSPA Signal Analyzer 4 28 PN 10580 00234 Rev V 3GPP MG ...
Page 272: ...5 19 Other Menus LTE Signal Analyzer 5 48 PN 10580 00234 Rev V 3GPP MG ...
Page 338: ...7 5 Coverage Mapping Menu LTE and TD LTE Coverage Mapping 7 16 PN 10580 00234 Rev V 3GPP MG ...
Page 354: ...8 4 W CDMA EMF Menu EMF Option 444 8 16 PN 10580 00234 Rev V 3GPP MG ...
Page 360: ...Index 4 PN 10580 00234 Rev V 3GPP MG ...
Page 361: ......