6-12 Measurements Menu
TD-LTE Signal Analyzer
6-42
PN: 10580-00234 Rev. V
3GPP MG
OTA Scanner Menu
Key Sequence:
Measurements
> Over-the-Air > Scanner > Scanner
Sort By:
Opens the Sort By list dialog. Choose one of the following
parameters to sort the Scanner table rows.
Cell ID
Group ID
Sector ID
S-SS Power
RSRP
RSRQ
SINR
Show Mod Results (Demod option required on some instruments):
Displays in table format the following measurements and information.
Ref. Signal (RS) Power
Sync Signal (SS) Power
EVM (rms)
EVM (pk)
Freq Error
Freq Error (ppm)
Carrier Frequency
Cell ID
Bar-Graph:
Opens the Bar Graph menu to select the parameter to be
displayed in the last (rightmost) column of the bar graph: SS Power, RSRP,
RSRQ or SINR. Press
Back
to return to the OTA Scanner menu.
Auto Save:
Use this submenu key to automatically save measurement
records. The instrument logs a data record at the end of each measurement
cycle. A maximum of 10,000 records can be stored in a file. When a file is
full, a new file is automatically created.
Files are automatically saved to the instrument’s Current Location selection
in the subdirectory /Internal Memory/user. Refer to the File Management
chapter in your instrument User Guide for instructions on setting the Current
Location for saving files.
File names are automatically created:
Yyyymmddhhnnss.tdlte
example:
2009081122332244.tdlte
y - year, 2009, m - month, 08, d - day, 11, h - hour, 22, n - minutes, 33
s - seconds, 44
Note: GPS coordinates are saved in addition to the measurement results,
if GPS is on and a fix is established.
Back:
Press this submenu key to return to the
.
Figure 6-36.
TD-LTE OTA Scanner Menu
Auto Save
On Off
Sort By
Power
Show Mod Results
On Off
OTA Scanner
Back
Bar-Graph
(SS Power)
Summary of Contents for BTS Master MT8221B
Page 1: ...BTS Master User Guide MT8221B and MT8222B The High Performance Handheld Base Station Analyzer ...
Page 2: ......
Page 4: ......
Page 6: ......
Page 8: ......
Page 24: ...1 12 Secure Environment Workplace General Information 1 10 PN 10580 00207 Rev E BTS Master UG ...
Page 46: ...2 13 Firmware Overview Instrument Overview 2 22 PN 10580 00207 Rev E BTS Master UG ...
Page 54: ...3 8 PN 10580 00207 Rev E BTS Master UG ...
Page 88: ...7 8 PN 10580 00207 Rev E BTS Master UG ...
Page 94: ...8 5 Updating Instrument Firmware Master Software Tools 8 6 PN 10580 00207 Rev E BTS Master UG ...
Page 95: ...Master Software Tools 8 5 Updating Instrument Firmware BTS Master UG PN 10580 00207 Rev E 8 7 ...
Page 96: ...8 5 Updating Instrument Firmware Master Software Tools 8 8 PN 10580 00207 Rev E BTS Master UG ...
Page 97: ...Master Software Tools 8 5 Updating Instrument Firmware BTS Master UG PN 10580 00207 Rev E 8 9 ...
Page 114: ...C 8 PN 10580 00207 Rev E BTS Master UG ...
Page 118: ...Index 4 PN 10580 00207 Rev E BTS Master UG ...
Page 152: ...2 18 Other Menus GSM GPRS EDGE Signal Analyzer 2 18 PN 10580 00234 Rev V 3GPP MG ...
Page 196: ...3 18 Other Menus W CDMA HSPA Signal Analyzer 3 44 PN 10580 00234 Rev V 3GPP MG ...
Page 224: ...4 16 Other Menus TD SCDMA HSPA Signal Analyzer 4 28 PN 10580 00234 Rev V 3GPP MG ...
Page 272: ...5 19 Other Menus LTE Signal Analyzer 5 48 PN 10580 00234 Rev V 3GPP MG ...
Page 338: ...7 5 Coverage Mapping Menu LTE and TD LTE Coverage Mapping 7 16 PN 10580 00234 Rev V 3GPP MG ...
Page 354: ...8 4 W CDMA EMF Menu EMF Option 444 8 16 PN 10580 00234 Rev V 3GPP MG ...
Page 360: ...Index 4 PN 10580 00234 Rev V 3GPP MG ...
Page 361: ......