 Solight 1T06 Breath Analyser User Manual 

Thank you for buying our digital breath analyser, which measures residual alcohol content in your breath and indicates 
the possible level of intoxication. The 1T06 model ranks among the professional measuring devices in its branch. It is 
equipped with a measuring sensor relying on the Fuel Cell technology, which is based on an electrochemical reaction 
of platinum and ethanol and is able to determine the alcohol content in breath with high accuracy of three decimal 
places of PPT. 

 

 

 

 

 

 

 

 

 

 

Instructions for use 

1.  Insert three 1.5V AAA size 

alkaline

 batteries into your device.  

2.  Prior to using the breath analyser, wash out your mouth with clean water. Do not smoke or drink alcohol for at 

least 10 minutes prior to measurement.  
!!! Measuring immediately or shortly after drinking alcohol is inaccurate and usually also causes damage to the 
sensitive measuring sensor. Claim due to this cause would be unjustified. 

3.  Extend the mouthpiece using the slider at the top of the device. Only this expandable mouthpiece can be used 

for testing. When testing several persons, for hygiene, put a blow-in tube onto the mouthpiece. Use a new blow-
in tube for each person. 

4.  Push power ON button to turn the device on. ALCO text will appear on the display. 
5.  By pushing the same button once again, you will start device heat-up. This stage includes an automatic testing 

chamber cleaning, sensor activation and the device will be ready for use after approx. 30 seconds. “PH” text will 
appear on the display, followed by a countdown sequence to zero - SH99 to 00 will appear on the display. At 
the end of the countdown, an audible signal will sound and “READY” and “BLOW” texts will start to flash. A 
countdown interval for blowing will appear on the display. If you do not start within approx. 30 seconds, the test 
will be cancelled. 

6.  Insert the mouthpiece into your mouth and blow-in uninterruptedly for around 5 to 7 seconds.  
7.  Stop blowing after an audible signal. The device will now start analysing, which is indicated by “ANLY” text 

flashing on the display. 

8.  The measured value will then appear on the display for 10 seconds and then gets stored into device memory. 

  Values are displayed with three decimal spaces; measurement deviation is ±0.008 ‰   

  A pre-set value of 0.2 ‰ will alert excess of the tolerated value limit for driving motor vehicles. “HI” and “Do 

not drive” icon will start flashing on the display. 

9.  If the air flow is too short or too weak, “FLO” will appear on the display and the test must be repeated. 

10.   For new measurement, press button again.

 

The device stores 20 measured values in its memory. 

11.   The measured values can be displayed by pushing the Up/Down buttons on the side of the device. 
12.   After five subsequent measurements, leave the device at standstill for 5 minutes. 
13.   By pushing the button for 2 seconds you will turn the device off. The device will power off automatically after 

approx. 30 seconds.  

 

 
 

Blow-in 
tube 

Up/Down 
buttons 

Power 
supply 
On/Off 

Extensible mouthpiece control 

Blow

Do not 
drive 

Measure
ment 
units 

Wait 

Ready 

Alcohol content exceeds 
pre-set limit 

Battery 
level 