To make the connection, connect the mains line to
the appliance's connection pipe, fitting a shut-off
tap (A), to allow the water supply to be cut off when
necessary. Easily accessible filters must be fitted
downstream of the tap.
Caution - warning
The appliance must be supplied with drinking
water having the characteristics shown in the
table.
(*) If the intake pressure exceeds 3 bar fit a pressure reducer.
WATER CONNECTION
Description
Value
Pressure
150÷300 kPa (1,5÷3 bar) (*)
pH
7÷7.5
Conductivity
< 200 mS/cm
Hardness
9÷13°f (5÷7°d, 6.3÷8.8°e,
90÷125 ppm)
Salt and metallic ion
content
Chlorides
Sulphates
Iron
Copper
Manganese
< 30 mg/l
< 40 mg/l
< 0,1 mg/l
< 0.05 mg/l
< 0,05 mg/l
To make the connection, connect the mains line to
the appliance's connection pipe, fitting a shut-off
tap (A), to allow the gas supply to be cut off when
necessary.
Important
The tap (A), not supplied with the appliance,
must be installed in an easily accessible
position and its status (on or off) must be
obvious at a glance.
This appliance shall be installed only by au-
thorised personnel and in accordance with
the manufacturer’s installation instruc-
tions, local gas fitting regulation municipal
building codes, water supply regulations,
electrical wiring regulations, AS 5601/AG
601 - Gas Installations and any other statu-
tory regulations.
GAS CONNECTION