The appliance is fitted with the controls for use of its
main functions.
A)Burner control knob: for lighting, turning off and
regulating the relative burner and pilot light
B)Water control knob: for filling the well in the various
ways available.
C)Ignition button: lights the pilot light.
D)Mains light: indicates that the appliance is receiving
electrical power.
DESCRIPTION OF CONTROLS
Lighting
1 - Turn on the gas supply tap.
2 - Press the knob (A) and turn it anti-clockwise
(pos. 1), while keeping button (B) pressed, to
light the pilot light.
3 - Keep the knob pressed for about 15 sec. to
prime the thermocouple.
4 - Turn the knob (A) anti-clockwise (pos. 2) to light
the burner.
5 - Turn the knob (A) gradually anti-clockwise to
adjust the power of the flame down to the mini-
mum setting (pos. 3).
Turning off
1 - Turn the knob clockwise (pos. 1) to turn the
burner off. The pilot light will remain on to allow
the burner to be re-lit.
2 - Turn the knob clockwise (pos. 4) to turn off the
pilot light.
3 - Turn off the knob to ensure safety.
SWITCHING THE BURNER ON AND OFF
C
IDM-396104900700.tif
Minimum pow-
er marker
Full power
marker
Off marker
A
Pilot light marker
B
Quick automatic
filling mark
Slow automatic
filling mark
Off marker
Manual filling mark
D
A
C
D
A
B
1
2
3
4
IDM-39614900800.tif
A B
A
Summary of Contents for 091CP1G