IT
AUS
DE
FR
ES
C
1
3
9
6
1
4
9
0
2
_
AU
S.
fm
- 21 -
English
To carry out this operation, proceed as follows.
1 - Turn off the gas supply tap.
2 - Open the hatch (A).
3 - Back off the screw (B) which secures the ring nut (C).
4 - Set the ring nut (C) at the distance (D) shown in
the table.
5 - Tighten the screw (B).
6 - After making the setting, seal the screw with paint.
7 - Close the door (A) when the operation is complete.
ADJUSTING BURNER PRIMARY AIR (091CP1G - 191CP2G)
Gas family
Distance (D) (mm)
Natural gas
26
Universal LPG
21
+
0
-
1
+
0
-
1
To carry out this operation, proceed as follows.
1 - Turn off the gas supply tap.
2 - Pull off the knob (A).
3 - Undo the screws (B) and remove the control
panel (C).
4 - Undo the screws (D) and extract the cap (E).
5 - Pull off the cone (F).
6 - Clean the cone (F) and its seat.
7 - Coat the cone with grease (F), fit it in its seat
and turn it a few times.
8 - Pull off the cone (F) to remove the excess grease.
9 - Replace the cone (F) and the cap (E).
10 - Replace the control panel (C) and the knobs (A)
on completion of the operation.
Before carrying out any replacement procedure, ac-
tivate all the safety devices provided and decide
whether staff at work and those in the vicinity
should be informed. In particular, turn off the gas
supply tap and prevent access to all devices which
might cause unexpected health and safety hazards
if turned on. If work parts have to be replaced, use
original spare parts only.
The manufacturer declines all responsibly for injury
or damage to components due to the use of non
original parts, or extraordinary work on the appli-
ance which may modify the safety requirements
without the manufacturer's authorisation.
When ordering components, follow the instructions
provided in the parts catalogue (to obtain spare
parts see back cover).
GREASING THE GAS TAP
REPLACING PARTS
9
RECOMMENDATIONS FOR REPLACING PARTS
IDM-39614901700.tif
B
D
A
C
IDM-39614602300.tif
B
C
E
F
D
A C