IT
GB
DE
FR
ES
- 12 -
C
1
3
9
6
1
4
9
0
2
_
AU
S.
fm
English
IT
AUS
DE
FR
ES
The appliance has been tested before being put
into service. The information provided below is in-
tended to assist in the identification and correction
of any anomalies and malfunctions which might oc-
cur during use.
The user can solve some of these problems him-
self, but for others specific technical knowledge or
skill is required, and so they must only be carried
out by qualified staff with recognised experience ac-
quired in the specific sector of operation.
FAULT
6
TROUBLESHOOTING
Faults
Causes
Remedies
Smell of gas
Occasional leak because flame has
gone out
Turn off the gas supply tap and
ventilate the room
The pilot light does not ignite
The spark ignition devices are not
working
Check that the ignition devices are in
good working order. Light by hand
with a naked light
Contact the after-sales service
Air in pipelines due to long period out
of use
Make more attempts to light the
flame
The pilot light goes out
The thermocouple has not warmed
up enough
Make more attempts to light the
flame
The flame is yellow
Burner dirty, heat exchange pipes
clogged, condensation drips
Contact the after-sales service
Burner control knob is stiff
Gas control valve malfunction
Contact the after-sales service
When the water control knob is
turned to 2 (automatic rapid filling),
water is supplied continuously,
until it overflows
Blockage in pressure switch circuit.
Contact the after-sales service
Pressure switch faulty
Filler solenoid valve faulty
When the water control knob is
turned to 2 (automatic rapid filling),
no water comes out of the tap
Pressure switch connection not made
correctly
Check the pressure switch
connection
Contact the after-sales service
Water connection not made correctly
Check the water connection
Contact the after-sales service
When the water control knob is
turned to 3 (automatic slow filling),
slow filling does not take place
Water level maintenance solenoid
valve connection not made correctly
Water level maintenance solenoid
valve faulty
Contact the after-sales service
Check the solenoid valve connection
Important
Important
Important
Important
Important
Important
Important
Summary of Contents for 091CP1G