C
1
39
6157
00
.f
m
English
See tables and "Connection chart" at the back of
the manual.
Although the appliance is complete with all safety
devices, during installation and connection addi-
tional devices must be added if necessary to com-
ply with the relevant legal requirements.
A)Automatic resetting Thermostat
: cuts off the
electricity supply in case of overheating. Once
the cause has been eliminated and temperature
is reduced, operation is restored automatically.
Caution - warning
Make a daily check that the safety devices are
properly installed and in good working order.
The illustration shows the position of the signs pro-
vided.
A)Nameplate with manufacturer and appliance
data
.
B)General hazard
: read the manual carefully before
carrying out any procedure.
C)General hazard
: when washing the appliance do
not point pressurised water jets at internal parts.
D)General hazard
: dry operation is forbidden.
E)General hazard
: all relevant regulations must be
complied with. "Install in compliance with the rele-
vant regulations and use in well ventilated premises
only".
F) General hazard
: all relevant regulations must be
complied with. "No liability is accepted in case of fail-
ure to comply with the installation and commission-
ing instructions".
G)CE marking
: indicates that the appliance is compli-
ant with the relevant norms.
H)WEEE symbol
: indicates that the appliance is sub-
ject to specific waste disposal regulations.
TECHNICAL DATA