9 - Apply the sealant to the inside of the lid
(F)
, and
fit it to cover the fixing zone.
10 - Replace the "insulation retainer" , if fitted.
11 - Replace the control panels
(B)
and the knobs
(A)
on completion of the operation.
A variety of optional installation kits are available for
arranging appliances in banks:
G)
"Over cupboard" installation kit
H)
"Bridge" installation kit
L)
Supporting beam kit
Important
The connection must be made by authorised,
skilled personnel, in accordance with the rel-
evant legal requirements, using appropriate
and specified materials. The appliance is
supplied with operating voltage 230V/1N,
which cannot be switched to other values.
Caution - warning
Before doing any work, cut off the mains elec-
tricity supply.
Connect the appliance to the mains electricity sup-
ply as follows.
1 - If not already present, install a circuit-breaker
(A)
with overload cutout and differential safety
breaker close to the appliance.
2 - Pull off the knob
(B)
.
3 - Undo the screws
(C)
and remove the control
panel
(D)
.
4 - Connect the circuit-breaker
(A)
to the terminal
board
(E)
of the appliance as shown in the dia-
gram and in the electrical system diagram at the
back of the manual. Use a flexible cable with at
least type H07RN-F characteristics, rated for an
operating temperature of at least 80°C.
Important
When connecting, take care to connect the
neutral and earth lines.
5 - Tighten the cable gland
(F)
.
6 - Replace the control panel
(D)
on completion of
the operation.
ELECTRICAL CONNECTION (090BM1E)